Page 30 of 60
Spirit Fires Limited. 4 Beaumont Square, Aycliffe Industrial Park, Newton Aycliffe, County
Durham, DL5 6XN. Tel : 01325-327221 Web :
www.spiritfires.co.uk
•
IF THE TEST IS FAILED:
If it is not possible to maintain the pressure
at the required level the problem may be caused by blockages in the
pipework, incorrect pipe sizing or a faulty meter. If the problem is the
meter then TRANSCO, BORD GAIS or the propane supplier must be
called to adjust the governor. Do not use the appliance until the issue
is rectified.
•
IF THE TEST IS PASSED:
Disconnect the pressure gauge, replace the
pressure test point sealing screw and test the appliance for gas
soundness. Refit the front shelf.
Fit the Ceramics to the Fire
The fire is supplied with Logs. Only the ceramics supplied with the fire can be
used.
Before the logs can be fitted the vanity cover needs to be refitted. Review the
procedure on Page 12. To refit reverse the procedure shown.