to a blocked flue. If this regularly occurs do not attempt to relight the
appliance until a qualified engineer has checked it.
•
The installation must be carried out by a Gas Safe registered engineer in
accordance with National Regulations.
•
The builders opening or fireplace opening must be constructed of a non-
combustible material.
•
Clearances between the fire and all combustible materials must conform to
National Regulations. Curtains must not be placed above the appliance and
must be a minimum of 1m away from the sides of the appliance.
•
This appliance is supplied as a complete fireplace package including gas fire
burner unit, enclosure and fascia. This fire must be installed and used in
accordance with these instructions.
•
For some countries a non-combustible hearth must be fitted in front of the
fire in accordance with National Regulations (e.g. United Kingdom).
•
Flue System:
The
FR920HE
can be used with a brick built chimney or a
lined flue with a minimum diameter of 125mm (5”). The chimney must have
a minimum effective height of at least 2 metres. The chimney should be
swept prior to installation if it has previously been used with solid fuel. This
is not necessary if the flue has previously been used with a gas appliance or
if it is a new installation. (see install section for full details on the flue
requirements). Any flue damper plate or flue restrictor must be removed.
•
Gas Supply:
The appliance is for use on Natural Gas (G20 @ 20mbar) only.
Inlet is via an 8mm gas line to the isolation valve provided with the fire. The
gas connections must be in accordance with National Regulations. If the gas
line is longer than 1.5mtrs then the gas line should be increased in diameter
to 15mm and possibly larger depending on the final length to ensure a
steady gas supply. The fire is supplied with an isolation valve inside the
appliance which must be used. When closed this allows the complete burner
and control assembly to be disconnected for maintenance or repair in
accordance with National Regulations.
•
The pilot light and flame sensing device fitted to this fire is also an
atmosphere sensing devise. If for any reason any part of the pilot assembly
is to be replaced ALL the assembly including the pilot burner, thermocouple,
electrode and injector must be exchanged complete for an original
manufacturer’s pilot assembly only. This atmosphere sensing devise is not
adjustable and must not be put out of action. The pilot light shuts off both
the main burner and pilot if evacuation of the combustion products is
interrupted (blocked chimney).
If the flame supervision device operates
no attempt should be made to re-light the gas fire until at least 3
minutes have elapsed. To relight the fire consult page 52.
If the
device operates again do not use the fire until the reason for operation is
found – consult a Gas Safe Engineer.
•
If the fire shuts itself off, do not use the fire, and have the flue and fire
checked by a suitably qualified person.
•
The
FR920HE
is battery operated; therefore no mains electrical supply is
required. Power to the appliance is provided by 3 high power alkaline 1.5V
batteries (AA size) these batteries can be changed to Nickel Metal Hydride