Page 4 of 60
Spirit Fires Limited. 4 Beaumont Square, Aycliffe Industrial Park, Newton Aycliffe, County
Durham, DL5 6XN. Tel : 01325-327221 Web :
www.spiritfires.co.uk
Introduction & Installation Requirements
.
Consumer Protection Information
As the manufacturer and supplier of heat products, we take every care, as far
as is reasonably practicable, that these products are so designed and
constructed as to meet the general safety requirement when properly used and
installed. To this end, our products are thoroughly tested and examined before
dispatch.
IMPORTANT NOTICE:
Any alteration that is not approved by the
appliance manufacturer could invalidate the approval of the appliance,
operation of the warranty and could affect your statutory rights.
Health and Safety Notice
Important:
This appliance could contain some of the materials, indicated
below, that could be interpreted as being injurious to health and safety. It is
the users / installers responsibility to ensure that the necessary personal
protective clothing is worn when handling these materials, see below for
information.
Artificial Fuels, Mineral Wool, Insulation Material, Refractory/Ceramic
Fibres, Glass Yarn
–
may be harmful inhaled, may be irritating to skin, eyes,
nose and throat.
When handling avoid inhaling and contact with skin or eyes. Use disposable
gloves, facemasks and eye protection. After handling wash hands and other
exposed parts. If a vacuum is used for cleaning the coals or cleaning after
servicing / installation it is recommended that it be of the type fitted with a
HEPA filter.
•
The
FR920HE
has been designed and tested to the requirements of EN613
and BS7977-1:2009 and is suitable for use in all EU countries with matching
gas categories.
•
The
FR920HE
is a high efficiency gas fire for use with a chimney or flue
system.
•
The
FR920HE
incorporates a single gas control, which selects ignition pilot,
with variable setting between low and high settings and is operated via
remote control hand set. The system is powered by a battery pack therefore
no mains electrical supply is required.
•
Like all appliances incorporating an aerated burner a low frequency noise
may be heard, this may be more noticeable on the low setting.
•
The
FR920HE
incorporates a safety device in the form of an Oxygen
Depletion System, which constantly monitors the oxygen in the room and
will cause the fire to switch off if the oxygen level reduces, for instance due
to a blocked flue. If this regularly occurs do not attempt to relight the
appliance until a qualified engineer has checked it.
•
The installation must be carried out by a Gas Safe registered engineer in
accordance with National Regulations.