NAVIGAT 100
056373/D
Service Setup 600
7-11
SENSOR DATA OUT
SENSOR DATA OUT 1-3, 5, 6
The SENSOR DATA OUT 1-3, 5 and 6 output settings are identical.
PROTOCOL TYPE
Settings:
NMEA
The sensor data out output setting is defined for transfer of
NMEA message type.
COURSE BUS
The sensor data out output setting is defined for transfer
using the serial Course Bus protocol at 9600 Bd.
NMEA TX PATTERN
Settings:
REPEATER
The NMEA output is defined as repeater protocol pattern.
SENSOR DATA 1
The NMEA output is defined as sensor data 1 pattern.
SENSOR DATA 2
The NMEA output is defined as sensor data 2 pattern.
SENSOR DATA 3
The NMEA output is defined as sensor data 3 pattern.
SENSOR DATA 4
The NMEA output is defined as sensor data 4 pattern
= default setting.
INDIVIDUAL
The NMEA output is to be defined individually.
NMEA BAUDRATE
Settings:
4800
The NMEA output is transferred at 4800 Bd
= default setting.
9600
The NMEA output is transferred at 9600 Bd.
38400
The NMEA output is transferred at 38400 Bd.