Initial System Configuration
6-11
Finalizing the Installation
1.
Go to the”Manual Settings Menu” on page 2-20.
2. Set the input data parameters in the Manual Settings menu to suita-
ble values. Wherever possible, automatic data input should be
selected in preference of manual input.
3. After configuration, go to the”Service Setup 998” on page 7-36 to
undertake hardware tests of the system equipment in operation. Use
the several test modes as described in the menu.
The test mode is functional even if the gyrosphere is not yet installed
(the baseplate test is however not functional without installed gyro-
sphere).
4. To bring the gyrocompass system into working order, the existing
alignment error must then be determined exactly and the error cor-
rection applied as described under ”Alignment Error Correction” on
page 6-12. and ”HEADING CORR. (Correction) VALUE” on page 7-7.
5. If required, determine the correction values for the magnetic com-
pass heading and enter the magnetic compass calibration table as
described under ”Magnetic Compass Calibration” on page 6-14.