056373/D
NAVIGAT 100
3-18
Alerts / check
838
A
ENC. COMM FAIL
GYRO
Encoder com-
munication
failed
•
Restart sys-
tem
•
Perform
baseplate
test
•
Call Sperry
Marine ser-
vice to
exchange
baseplate if
error persists
842
A
BASEPLATE
GYRO
Baseplate test
during system
start failed
•
Restart sys-
tem
•
Call Sperry
Marine ser-
vice to
exchange
baseplate if
error persists
846
W
CALIBRATION
GYRO
Bridge voltage
calibration
faulty
Replace optical
pick-off PCBs
850
W
BV-SAMPLE RANGE
GYRO
Bridge voltage
in warning
range during
calibration
•
Restart sys-
tem
•
If error per-
sists, call
Sperry
Marine ser-
vice to
exchange the
optical pick
offs of the
gyrosphere
container
(mod. 10/3)
854
W
ANNUAL OVERHAUL
GYRO
Operation time
counter limit
reached
Apply gyro-
sphere mainte-
nance
862
A
OPTICAL SAMPLE
GYRO
No connection
to Mod. 10/4
Gyro optical
sampling
Check Mod. 10/4
container
866
W
MANUAL TURN
MODE
GYRO
S-4 GYRO DIP-
Switch set.
Correct GYRO ID
DIP-Switch set-
tings
Alert
ID
Alert
Type
Alert Text
Cause
Corrective
Action
Summary of Contents for NAVIGAT 100
Page 38: ...056373 D NAVIGAT 100 1 20 Declaration of Conformity...
Page 90: ...056373 D NAVIGAT 100 4 4 Gyrosphere Maintenance...
Page 120: ...056373 D NAVIGAT 100 6 20 Installation Check Procedures...
Page 176: ...056373 D NAVIGAT 100 9 14 NAVIGAT 100 Software Update...
Page 190: ...056373 D NAVIGAT 100 XII...
Page 200: ......
Page 204: ......
Page 207: ......
Page 208: ......
Page 209: ......
Page 210: ......
Page 211: ......