NAVIGAT 100
056373/D
Alert Handling
3-7
Rectified Acknowledged Alarm
After a rectified alarm is acknowledged,
or an acknowledged alarm becomes rec-
tified, it is displayed for another 3 sec-
onds before it disappears.
The display continuous to show the
heading data from the selected compass
(GYRO respectively MAGN).
The sign for inactive acknowledged
alarm,
„ALARM“ followed by the number of
current alerts, the alert ID of the respec-
tive alarm and the corresponding alarm
message will be indicated for three sec-
onds only and is completely cleared
afterwards.
The arrow symbols (
) indicate that the
Left (
) / Right (
)
keys are to
be used for scrolling forward and back displaying the alarm messages in
the alert list.
356.4°
ALARM 1/2
GYRO1
ID:511
TIMEOUT
GPS1
Note
When an alarm has been acknowledged, the external alarm status output
remains active until the cause of the alarm is eliminated.
When a cause of a pending unacknowledged alarm is eliminated, the
alarm stays in the alert list for fault diagnostics.
The NAVIGAT 100 does not keep a history of acknowledged inactive
alarms.