NAVIGAT 100
056373/D
Example System Configurations
1-13
DIP-Switch Settings
For the usage of the respective Gyrosphere Container model (Mod. 10/3
or Mod. 10/4) with the NAVIGAT 100, it is required to appropriately set
the DIP-Switch S3 directly on the NAVIGAT 100 mainboard before the
installation of the respective Gyrosphere Container model.
An overview of the NAVIGAT 100 DIP-switch settings S3 is shown in
figure 1-13 below.
Figure 1-13:
NAVIGAT 100
DIP-Switch settings
S3
CAUTION
Risk of misusage
Changing the DIP switch settings during operation will impair the system
operability following the next system power up.
Never change DIP switch settings during operation.
Always set the DIP switch settings before the operation of the system.
Always set the DIP switch settings according to the requirements of the
respective gyrosphere container model in usage.
1 2
ON
0 0
NG 100
DIP-Switch Settings S3
3
1
1 2
ON
0 0
Mod.
10/3
3
0
Mod.
10/4
Note
The S1 / S2 DIP-Switches are not applicable for usage with the
NAVIGAT 100 gyrocompass system and have no influence for the opera-
bility of the gyrocompass.