182
(c) Spectrum Instrumentation GmbH
Details on M2p cards I/O lines
Due to the programmable threshold level of the M2p card, the M4i/M4x clock output can be directly connected to the M2p DC-coupled clock
input, when setting the threshhold to zero Volt.
For best signal integrity and minimizing reflections due to the very fast edge rates of the M4i/M4x LVPECL output, activating the 50 Ohm
termination on the M2p card is highly recommended.