Error Codes
Appendix
Appendix
Error Codes
The following error codes could occur when a driver function has been called. Please check carefully the allowed setup for the register and
change the settings to run the program.
Table 102: Spectrum API: driver error codes and error description
error name
value
(hex)
value
(dec.)
error description
ERR_OK
0h
0
Execution OK, no error.
ERR_INIT
1h
1
An error occurred when initializing the given card. Either the card has already been opened by another process or
an hardware error occurred.
ERR_TYP
3h
3
Initialization only: The type of board is unknown. This is a critical error. Please check whether the board is correctly
plugged in the slot and whether you have the latest driver version.
ERR_FNCNOTSUPPORTED
4h
4
This function is not supported by the hardware version.
ERR_BRDREMAP
5h
5
The board index re map table in the registry is wrong. Either delete this table or check it carefully for double values.
ERR_KERNELVERSION
6h
6
The version of the kernel driver is not matching the version of the DLL. Please do a complete re-installation of the hard
-
ware driver. This error normally only occurs if someone copies the driver library and the kernel driver manually.
ERR_HWDRVVERSION
7h
7
The hardware needs a newer driver version to run properly. Please install the driver that was delivered together with
the card.
ERR_ADRRANGE
8h
8
One of the address ranges is disabled (fatal error), can only occur under Linux.
ERR_INVALIDHANDLE
9h
9
The used handle is not valid.
ERR_BOARDNOTFOUND
Ah
10
A card with the given name has not been found.
ERR_BOARDINUSE
Bh
11
A card with given name is already in use by another application.
ERR_EXPHW64BITADR
Ch
12
Express hardware version not able to handle 64 bit addressing -> update needed.
ERR_FWVERSION
Dh
13
Firmware versions of synchronized cards or for this driver do not match -> update needed.
ERR_SYNCPROTOCOL
Eh
14
Synchronization protocol versions of synchronized cards do not match -> update needed
ERR_LASTERR
10h
16
Old error waiting to be read. Please read the full error information before proceeding. The driver is locked until the
error information has been read.
ERR_BOARDINUSE
11h
17
Board is already used by another application. It is not possible to use one hardware from two different programs at
the same time.
ERR_ABORT
20h
32
Abort of wait function. This return value just tells that the function has been aborted from another thread. The driver
library is not locked if this error occurs.
ERR_BOARDLOCKED
30h
48
The card is already in access and therefore locked by another process. It is not possible to access one card through
multiple processes. Only one process can access a specific card at the time.
ERR_DEVICE_MAPPING
32h
50
The device is mapped to an invalid device. The device mapping can be accessed via the Control Center.
ERR_NETWORKSETUP
40h
64
The network setup of a digitizerNETBOX has failed.
ERR_NETWORKTRANSFER
41h
65
The network data transfer from/to a digitizerNETBOX has failed.
ERR_FWPOWERCYCLE
42h
66
Power cycle (PC off/on) is needed to update the card's firmware (a simple OS reboot is not sufficient !)
ERR_NETWORKTIMEOUT
43h
67
A network timeout has occurred.
ERR_BUFFERSIZE
44h
68
The buffer size is not sufficient (too small).
ERR_RESTRICTEDACCESS
45h
69
The access to the card has been intentionally restricted.
ERR_INVALIDPARAM
46h
70
An invalid parameter has been used for a certain function.
ERR_TEMPERATURE
47h
71
The temperature of at least one of the card’s sensors measures a temperature, that is too high for the hardware.
ERR_REG
100h
256
The register is not valid for this type of board.
ERR_VALUE
101h
257
The value for this register is not in a valid range. The allowed values and ranges are listed in the board specific docu
-
mentation.
ERR_FEATURE
102h
258
Feature (option) is not installed on this board. It’s not possible to access this feature if it’s not installed.
ERR_SEQUENCE
103h
259
Command sequence is not allowed. Please check the manual carefully to see which command sequences are possi
-
ble.
ERR_READABORT
104h
260
Data read is not allowed after aborting the data acquisition.
ERR_NOACCESS
105h
261
Access to this register is denied. This register is not accessible for users.
ERR_TIMEOUT
107h
263
A timeout occurred while waiting for an interrupt. This error does not lock the driver.
ERR_CALLTYPE
108h
264
The access to the register is only allowed with one 64 bit access but not with the multiplexed 32 bit (high and low
double word) version.
ERR_EXCEEDSINT32
109h
265
The return value is int32 but the software register exceeds the 32 bit integer range. Use double int32 or int64
accesses instead, to get correct return values.
ERR_NOWRITEALLOWED
10Ah
266
The register that should be written is a read-only register. No write accesses are allowed.
ERR_SETUP
10Bh
267
The programmed setup for the card is not valid. The error register will show you which setting generates the error mes
-
sage. This error is returned if the card is started or the setup is written.
ERR_CLOCKNOTLOCKED
10Ch
268
Synchronization to external clock failed: no signal connected or signal not stable. Please check external clock or try to
use a different sampling clock to make the PLL locking easier.
ERR_MEMINIT
10Dh
269
On-board memory initialization error. Power cycle the PC and try another PCIe slot (if possible). In case that the error
persists, please contact Spectrum support for further assistance.
ERR_POWERSUPPLY
10Eh
270
On-board power supply error. Power cycle the PC and try another PCIe slot (if possible). In case that the error persists,
please contact Spectrum support for further assistance.
ERR_ADCCOMMUNICA
-
TION
10Fh
271
Communication with ADC failed.P ower cycle the PC and try another PCIe slot (if possible). In case that the error per
-
sists, please contact Spectrum support for further assistance.
ERR_CHANNEL
110h
272
The channel number may not be accessed on the board: Either it is not a valid channel number or the channel is not
accessible due to the current setup (e.g. Only channel 0 is accessible in interlace mode)