(10.1.100.1 and 10.1.100.2 with a subnet value of 255.255.255.0 on both
devices, for example). For more information on configuring static IP addresses,
see "Assigning a Static IP Address" on page 44.
Once the unit is up and running, verify that the
green
link light on the Ethernet port is illu
minated. The
amber
“Activity” link light may periodically illuminate when network traffic is
present.
2.9
Connecting Inputs and Outputs
NetClock can synchronize not only to an external GNSS reference signal, but also to other
optional external references such as IRIG, HAVE QUICK and ASCII inputs (in addition to net
work based references such as NTP and/or PTP).
At the same time, NetClock can output timing and frequency signals for the consumption by
other devices via the same formats as listed above.
E X A M P L E :
With the available IRIG Input/Output option card module (Model 1204-05) installed in an option
bay, IRIG time code from an IRIG generator can also be applied as an external reference input (either
in addition to, or in lieu of GNSS, NTP, user set time and other available reference inputs).
To use e.g., an external IRIG reference, connect the IRIG time source to the BNC connector “J1”
on the optional IRIG Input/Output module. For additional information on optional connectivity,
such as pinout tables, signal levels and other specifications, see "Option Modules" on
page 335.
Note that some option cards offer both input and output functionality, while others offer only
one or the other.
2.10
Powering Up the Unit
1.
After installing your NetClock unit, verify that power is connected, then turn ON the unit
using the switch on the rear panel, and wait for the device to boot up.
Note:
NetClock 9483 only:
DC input power
is not switched, so NetClock
will be powered up with DC input connected, unless you installed an
external power switch.
2.
Observe that all of the front panel LEDs momentarily illuminate (the Power LED will then
stay lit) and that the Information display LCD back light illuminates. The fan may or may
not run, depending on the model year of your NetClock unit. For more information, see
2.9 Connecting Inputs and Outputs
CHAPTER
2
•
NetClock User Reference Guide
Rev.
16
41
Summary of Contents for NetClock 9400 Series
Page 2: ......
Page 4: ...Blank page II NetClock User Reference Guide...
Page 16: ...BLANK PAGE XIV NetClock User Reference Guide TABLE OF CONTENTS...
Page 42: ...BLANK PAGE 1 11 Regulatory Compliance 26 CHAPTER 1 NetClock User Reference Guide Rev 16...
Page 160: ...BLANK PAGE 2 17 Configuring Outputs 144 CHAPTER 2 NetClock User Reference Guide Rev 16...
Page 238: ...BLANK PAGE 3 5 Managing the Oscillator 222 CHAPTER 3 NetClock User Reference Guide Rev 16...
Page 462: ...BLANK PAGE 446 NetClock User Reference Guide...