Local Clocks panel
You can create multiple different Local Clocks, as needed. The names of all Local Clocks that
have already been created are displayed in the Local Clocks panel.
See also "Local Clock(s), DST" on page 157.
3.2
System Time
The time that NetClock maintains is referred to as the
System Time
. The System Time is used to
supply time to all of the available time-of-day outputs (such as the front panel LED display, NTP
time stamps, time stamps in the log entries, ASCII data outputs, etc.)
By default, the System Time is synchronized to NetClock’s input references (such as GNSS,
IRIG, ASCII data, NTP, PTP, etc.).
If a UTC-based time is not required, however, it is also possible to manually set the System Time
to a desired time/date, or to use the unit's battery backed time (Real Time Clock) as System
Time (with an external 1PPS reference).
The flow chart below illustrates how NetClock obtains the highest available and valid ref
erence, depending on whether an external source is chosen as reference, or an internal (
User
[x]
, or
Local System
).
Figure 3-1:
How the System Time is derived
Note:
User hand-set times can only be set in UTC (not Local time).
3.2 System Time
CHAPTER
3
•
NetClock User Reference Guide
Rev.
16
147
Summary of Contents for NetClock 9400 Series
Page 2: ......
Page 4: ...Blank page II NetClock User Reference Guide...
Page 16: ...BLANK PAGE XIV NetClock User Reference Guide TABLE OF CONTENTS...
Page 42: ...BLANK PAGE 1 11 Regulatory Compliance 26 CHAPTER 1 NetClock User Reference Guide Rev 16...
Page 160: ...BLANK PAGE 2 17 Configuring Outputs 144 CHAPTER 2 NetClock User Reference Guide Rev 16...
Page 238: ...BLANK PAGE 3 5 Managing the Oscillator 222 CHAPTER 3 NetClock User Reference Guide Rev 16...
Page 462: ...BLANK PAGE 446 NetClock User Reference Guide...