Spectracom Corporation
Model 9289
NetClock/NTP Network Time Provider Instruction Manual
2-1
2
Installation
2.1
Summary
This section provides an overview summary of the installation process. The installation of the
NetClock consists of the following steps. Refer to the table of contents in this manual for
specific section references detailing how these summarized steps are accomplished.
WARNING:
This equipment has a connection between the earthed
conductor of the DC supply circuit and the earthing conductor.
This equipment shall be connected directly to the DC supply
system earthing electrode conductor or to a bonding jumper
from an earthing terminal bar or bus to which the DC supply
system earthing electrode conductor is connected.
This equipment shall be located in the same immediate area
(such as, adjacent cabinets) as any other equipment that has
a connection between the earthed conductor of the same DC
supply circuit and the earthing conductor, and also the point of
earthing of the DC system. The DC system shall not be
earthed elsewhere.
The DC supply source is to be located within the same
premises as this equipment.
Switching or disconnected devices shall not be in the earthed
circuit conductor between the DC source and the point of the
connection of the earthing electrode conductor.
CAUTION:
Electronic equipment is sensitive to Electrostatic Discharge
(ESD). Observe all ESD precautions and safeguards when
handling Spectracom equipment.
CAUTION:
Once power is applied to the unit, DO NOT disconnect power
unless the HALT command is first issued to the NetClock.
Refer to Product Configuration for information on issuing the
HALT command.
1)
If desirable, install the rack-mount ears on the two sides of the front panel and install the
unit in a standard 19 inch rack cabinet.
Summary of Contents for 9289
Page 18: ...Model 9289 Spectracom Corporation NetClock NTP Network Time Provider Instruction Manual 1 8...
Page 36: ...Model 9289 Spectracom Corporation NetClock NTP Network Time Provider Instruction Manual 2 18...
Page 154: ...Model 9289 Spectracom Corporation NetClock NTP Network Time Provider Instruction Manual 3 118...