Spectracom Corporation
Model 9289
NetClock/NTP Network Time Provider Instruction Manual
3-57
NOTE:
Any remote Syslog server that is entered to receive log messages must be properly
configured to accept incoming Syslog messages.
3.4.14 Configuring and Testing Relays
The Relay menu groups the NetClock’s relay functions (Figure 3-55). From this menu, the user
may access screens configure, test, and reset the relay outputs and event timers.
Figure 3-55: Relay Menu
The operational status can be monitored remotely using the TIMER/ALARM RELAYS connector
on the rear panel. This connector provides the common, NO and NC contacts for three relays.
These relays can be connected to an alarm lamp, horn, or other indicator to warn when the
clock accuracy or operation has been affected, or to signal the triggering of a programmed
event. The relay contacts are rated at 2.0 amps, 30VDC.
The web browser user interface allows the assignment to each relay of one of three functions:
Major Alarm, Minor Alarm, and Event Timer.
To assign a function to a relay, click the radio button that lines up with both the function and the
relay.The relay operation of all three relays can be tested at any time as desired. To test the