Model 9289
Spectracom Corporation
NetClock/NTP Network Time Provider Instruction Manual
3-58
relay operation, login as administrator mode and click on “test relays” in the left orange bar.
Chose the desired relay to be tested and then press submit. The selected relay should activate
each time the submit button is pushed.
NOTE:
A single relay can only be assigned one function but a function can be assigned to
multiple relays. By default, all three relays are assigned “Major Alarm.”
Figure 3-56: Relay Output Screen
The Event Timer Relay screen (Figure 3-57) and the Relay Current Event Scheduler screen
(Figure 3-59) allow for the configuration of 128 events that can turn on or off any one of the
event timer relays. Make sure the rear panel relay that is going to be associated with an event is
configured to be the event timer relay in order to use this feature.
If any events are already configured, they will be displayed by event number. There are no
requirements on the order of the events; each one is completely independent of the others.
Enter the number of the event that you wish to edit/view and click the Edit/View button.