background image

Notices

2

Notices

Except as expressly stated herein, Spectra Logic Corporation makes its products and associated documentation on an “AS IS” 
BASIS, WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED 
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, BOTH OF WHICH ARE EXPRESSLY DISCLAIMED. 
In no event shall Spectra Logic be liable for any loss of profits, loss of business, loss of use or data, interruption of business, or 
for indirect, special, incidental or consequential damages of any kind, even if Spectra Logic has been advised of the possibility of 
such damages arising from any defect or error.

Information furnished in this manual is believed to be accurate and reliable. However, no responsibility is assumed by 
Spectra Logic for its use. Due to continuing research and development, Spectra Logic may revise this publication from time 
to time without notice, and reserves the right to change any product specification at any time without notice.
If you do not agree to the above, do not use the Spectra nTier300; instead, promptly contact Spectra Logic for instructions 
on how to return the Spectra nTier300 for a refund.

BlueScale, Spectra, SpectraGuard, TeraPack, and the Spectra Logic logo are registered trademarks and RXT is a trademark 
of Spectra Logic Corporation. All rights reserved worldwide. All other trademarks and registered trademarks are the 
property of their respective owners.

Spectra nTier300 Virtual Tape Library Appliance Installation Guide
Revision B, July 2008

Copyright © 2008 Spectra Logic Corporation. All rights reserved.

License

You have acquired a Spectra product that includes software owned or licensed by Spectra Logic from one or more 
software licensors (“Software Suppliers”). Such software products, as well as associated media, printed materials 
and “online” or electronic documentation (“SOFTWARE”) are protected by copyright laws and international 
copyright treaties, as well as other intellectual property laws and treaties. 

If you do not agree to this end user license agreement (EULA), do not use the Spectra Product; instead, promptly contact 
Spectra Logic for instructions on return of the Spectra Product for a refund. Any use of the Software, including but not 
limited to use on the Spectra Product, will constitute your agreement to this EULA (or ratification of any previous consent).

Grant of License.

 The Software is licensed on a non-exclusive basis, not sold. This EULA grants you the following rights to 

the Software:

ƒ

You may use the Software only on the Spectra Product.

ƒ

Not Fault Tolerant.

 The Software is not fault tolerant. Spectra Logic has independently determined how to use the 

Software in the Spectra Product, and suppliers have relied upon Spectra Logic to conduct sufficient testing to determine 
that the Software is suitable for such use.

ƒ

No Warranties for the SOFTWARE.

 The Software is provided “AS IS” and with all faults. The entire risk as to 

satisfactory quality, performance, accuracy, and effort (including lack of negligence) is with you. Also, there is no 
warranty against interference with your enjoyment of the Software or against infringement. If you have received any 
warranties regarding the SOFTWARE, those warranties do not originate from, and are not binding on Software suppliers.

ƒ

Note on Java Support.

 The Software may contain support for programs written in Java. Java technology is not fault 

tolerant and is not designed, manufactured, or intended for use of resale as online control equipment in hazardous 
environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation or 
communications systems, air traffic control, direct life support machines, or weapons systems, in which the failure of 
Java technology could lead directly to death, personal injury, or severe physical or environmental damage. 

ƒ

No Liability for Certain Damages.

 Except as prohibited by law, Software suppliers shall have no liability for any 

indirect, special, consequential or incidental damages arising from or in connection with the use or performance of the 
Software. This limitation shall apply even if any remedy fails of its essential purpose. In no event shall Software 
suppliers, individually, be liable for any amount in excess of U.S. two hundred fifty dollars (U.S. $250.00).

ƒ

Limitations on Reverse Engineering, Decompilation, and Disassembly.

 You may not reverse engineer, decompile, or 

disassemble the Software, except and only to the extent that such activity is expressly permitted by applicable law 
notwithstanding this limitation.

ƒ

Software Transfer Allowed with Restrictions.

 You may permanently transfer rights under this EULA only as part of a 

permanent sale or transfer of the Spectra nTier300, and only if the recipient agrees to this EULA. If the Software is an 
upgrade, any transfer must also include all prior versions of the Software.

ƒ

Export Restrictions.

 Export of the Software from the United States is regulated by the Export Administration 

Regulations (EAR, 15 CFR 730-744) of the U.S. Commerce Department, Bureau of Export Administration. You agree to 
comply with the EAR in the export or re-export of the Software: (i) to any country to which the U.S. has embargoed or 
restricted the export of goods or services, which as May 1999 include, but are not necessarily limited to Cuba, Iran, Iraq, 
Libya, North Korea, Sudan, Syria, and the Federal Republic of Yugoslavia (including Serbia, but not Montenegro), or to 
any national or any such country, wherever located, who intends to transit or transport the Software back to such 
country; (ii) to any person or entity who you know or have reason to know will utilize the Software or portion thereof 
in the design, development or production of nuclear, chemical, or biological weapons; or (iii) to any person or entity 
who has been prohibited from participating in U.S. export transactions by any federal agency of the U.S. government. 
You warrant and represent that neither the BXA nor any other U.S. federal agency has suspended, revoked or denied 
your export privileges. For additional information see 

http://www.microsoft.com/exporting/

.

Summary of Contents for Spectra nTier300

Page 1: ...Spectra nTier300 Virtual Tape Library Appliance Installation Guide PN 90990034 Revision B...

Page 2: ...sfactory quality performance accuracy and effort including lack of negligence is with you Also there is no warranty against interference with your enjoyment of the Software or against infringement If...

Page 3: ...haben k nnen Nur geschultes Personal sollte die Hochspannungskomponenten warten oder installieren Moving the nTier300 VTL Warning The nTier300 VTL weighs approximately 54 lb 25 kg without drives inst...

Page 4: ...rt web Site www spectralogic com support index cfm Knowledge Base www spectralogic com support kbase index cfm United States and Canada Phone 800 227 4637 E mail support spectralogic com Europe Middle...

Page 5: ...ftware 16 Spectra BlueScale Web Interface 16 Chapter 2 Installing the nTier300 VTL 17 Preparing for the Installation 17 Unpacking the nTier300 VTL 18 Prepare the Unpacking Location 18 Unpack the Compo...

Page 6: ...le Status Icons 42 Viewing Messages 42 Monitoring the Status of Components 45 Viewing and Configuring IP Addresses 48 Restarting or Shutting Down the nTier300 VTL 50 Chapter 4 Maintenance 53 Replacing...

Page 7: ...on Period 65 Product Relocation 65 Appendix B Specifications 67 RAID Storage Specifications 67 Integrated Server 68 Size and Weight 68 Power Requirements 69 Input Power Requirements 69 Power Cord Spec...

Page 8: ...Contents 8 Notes...

Page 9: ...ith the nTier300 VTL for detailed information about configuring and using one or more virtual tape libraries using the FalconStor VTL Console referred to as the VTL Console Intended Audience This guid...

Page 10: ...uide which is included as a PDF on the nTier Deduplication CD included with the nTier300 VTL provides detailed information and instructions for using the Falcon for configuring managing and troublesho...

Page 11: ...features nTier FalconStor VTL software The included FalconStor VTL software provides Virtual Tape Library VTL and FalconStor Single Instance Repository SIR deduplication functionality for the nTier30...

Page 12: ...formance dual core CPU running the FalconStor VTL software Gigabit 1000BaseT Ethernet connectivity Two on board Gigabit Ethernet ports provide connections to Ethernet networks These ports provide iSCS...

Page 13: ...in place LEDs on each drive sled indicate the status of the drive Drive blanks When fewer than twelve data drives are installed the bottom rows of drive bays have drive blanks installed to prevent co...

Page 14: ...upply has its own AC power connector Cord locks on each power cord secure the cord to prevent it from being inadvertently disconnected Each power supply has a single LED that lights to indicate when t...

Page 15: ...r300 VTL for saving configurations and uploading firmware packages If desired you can use these ports to connect a USB mouse and a USB keyboard to the nTier300 VTL integrated server Expansion slots Tw...

Page 16: ...the Implementing nTier Deduplication guide which is included as a PDF on the nTier Deduplication CD Spectra BlueScale Web Interface The BlueScale web interface shown in Figure 1 4 provides an interfa...

Page 17: ...available The nTier300 VTL requires a minimum of one Ethernet connection to provide the FalconStor VTL Console access to the nTier300 VTL and for accessing the BlueScale web interface It also require...

Page 18: ...rpeted floor or anywhere else that poses risk for static discharge that could damage your appliance and its drives Unpacking the nTier300 VTL The Spectra nTier300 VTL and its drives are shipped in a c...

Page 19: ...nTier300 VTL has not been improperly handled before proceeding Figure 2 5 Caution Do not unpack the nTier300 VTL or its drives if the Tip N Tell or Shockwatch indicator has been tripped Contact both t...

Page 20: ...oder Fortbewegen Caution Leave the drives in their anti static bags until you have unpacked and installed the chassis in a rack Always wear an anti static wristband attached to an unpainted metallic s...

Page 21: ...er300 VTL configuration for either 110 VAC or 220 VAC operation See Power Cord Specifications on page 69 for information about the power cords Drives The number of drives depends on the configuration...

Page 22: ...nTier300 VTL in der N he der Unterseite des Schranks zu verhindern dass der Schrank von der kopflastigen Before You Begin Obtain the following tools and equipment 2 Phillips screwdriver magnetic if av...

Page 23: ...ews Attach rail assemblies to rack Bag labeled 3 4 large nut plates 12 or more screws Attach rail assemblies to rack Bag labeled 4 4 clip nuts 4 screws Secure nTier300 VTL to rack Component Required U...

Page 24: ...he second rail assembly Install the Sliders on the Chassis 1 Remove the nTier300 VTL chassis from its bag and place it on a sturdy work surface where you can reach both sides of the chassis Having two...

Page 25: ...to each of the circled three holes as shown in Figure 2 11 This secures the slider to the chassis Tighten the screws snugly If the circled holes don t align properly with chassis screw holes install t...

Page 26: ...st the rack side with the extender nearest the back of the rack 3 Adjust the extender so that it just fits in the inside distance from the front mounting holes of your rack to the back mounting holes...

Page 27: ...to hold the plate in place 4 Repeat Step 3 to install the nut plates on the each of the other three posts of the rack Note Make sure that the nut plates are installed at the same level on all four po...

Page 28: ...at Step 5 to attach the second outer rail to the rack Set aside any leftover screws and parts 7 On the front of the rack attach two clip nuts from bag 4 to each leg Place one above and another below t...

Page 29: ...VTL weighs approximately 54 lb 25 kg without drives installed Use extreme caution when moving it Always use two people one on each side when lifting or moving it Warnung Die nTier300 VTL wiegt ca 25 k...

Page 30: ...drives into the drive bays in any particular order The drive mapping for the RAID volume in the nTier300 VTL is dynamic The system determines the position of each drive during the first system boot an...

Page 31: ...painted metal chassis Leave the drives in their anti static bags until you are ready to install them Do not place un bagged drives on any metal surfaces Do not power on the nTier300 VTL until all of t...

Page 32: ...the cables to the system and perform the initial power up 1 Connect an Ethernet cable to either Ethernet port 1 or 2 on the rear panel Connect the other end of the cable to an active network over whic...

Page 33: ...your switch to an optional 10 GigE NIC installed in the nTier300 VTL 3 If desired connect the nTier300 VTL to a physical library a standalone tape drive or another nTier VTL appliance If your physical...

Page 34: ...nt cover 2 Examine the back of the cover Using the keys position of the locking tabs on each end so they are in the unlocked position Figure 2 21 3 Hold the edges of the cover and orient it so that th...

Page 35: ...ale web interface If you connected the computer running the VTL Console to the nTier300 VTL using Ethernet port 2 use IP address 192 168 1 2 to connect to the server through the VTL Console and to acc...

Page 36: ...Chapter 2 Installing the nTier300 VTL 36 Notes...

Page 37: ...eb Interface on page 40 Monitoring the Status of Components on page 45 Viewing and Configuring IP Addresses on page 48 Restarting or Shutting Down the nTier300 VTL on page 50 Powering On the Spectra n...

Page 38: ...Restarting or Shutting Down the nTier300 VTL on page 50 Accessing the BlueScale Web Interface The BlueScale web interface lets you configure network connections to the nTier300 VTL monitor the status...

Page 39: ...web site s security certificate displays Figure 3 2 shows an example warning from Internet Explorer 7 The format of the warning may be different with the web browser you are using The warning displays...

Page 40: ...sion Using the BlueScale Web Interface The BlueScale web interface lets you configure the nTier300 VTL network connections and monitor the status of system components The BlueScale web server starts a...

Page 41: ...of the status icons Unread messages The number of unread messages if any displays on the Message button Selecting the Messages button displays a list of all the current messages see Viewing Messages...

Page 42: ...tton shown in Figure 3 5 indicates that there are 30 unread messages The Error icon indicates that at least one of the messages is an error notification Reading Messages Use the following steps to vie...

Page 43: ...r of messages that have been marked as read if any 3 Select Unread Messages to expand the list of unread messages Figure 3 6 Pay extra attention to any message flagged with the Warning or Error icon a...

Page 44: ...ist and select Mark All as Read Figure 3 7 The number and the status icon shown on the Messages button are updated to reflect the status of any new messages Selecting Mark All as Read moves the messag...

Page 45: ...ed status information for individual components The ability to monitor components status using the BlueScale web interface is especially useful when your nTier300 VTL is operating in a lights out data...

Page 46: ...component in the group requires attention Red A component in the group is in an error state Figure 3 10 Tab Shows Drives Overall status for all drives Status of each drive Fans Status of midplane fans...

Page 47: ...igure 3 10 changes the graphic to show the components associated with DRIVES Selecting Drives from the list below the graphic expands the page to show a list of the drives Figure 3 11 in the system An...

Page 48: ...ht use one network connection for archiving virtual tapes to physical tapes in a library connected to the network Note You can use ether Ethernet port 1 or 2 to access the nTier300 VTL from the VTL Co...

Page 49: ...n nnn Subnet Enter a valid subnet mask in the form of nnn nnn nnn nnn Gateway Enter a valid Class A B or C network gateway address in the form of nnn nnn nnn nnn Enter 0 0 0 0 if your network does not...

Page 50: ...the button s LED turns off Press the button again power the nTier300 VTL back on again Caution Do not use the power button to turn off the nTier300 VTL unless you are specifically instructed to do so...

Page 51: ...lt wait for approximately 90 seconds for the VLT console to stop the operating system then press power button until the blue LED in the button turns off Note To completely power off your nTier300 VTL...

Page 52: ...Chapter 3 Using the nTier300 VTL BlueScale Web Interface 52 Notes...

Page 53: ...lication guide for instructions Estimated Time Required Replacing a data drive takes about ten minutes This procedure can be performed without interrupting the operation of the nTier300 VTL As soon as...

Page 54: ...ata drive to Spectra Logic Recommended An anti static mat Identify the Malfunctioning Drive 1 Log into the local nTier300 VTL BlueScale web interface see Accessing the BlueScale Web Interface on page...

Page 55: ...throughout the procedure If a wristband is not available touch a known grounded surface such as the unpainted metal chassis An anti static wristband is included with the accessories Leave the drive in...

Page 56: ...ds potential damage Use the following steps if you need to remove a drive 1 Slide the sled latch to the right to release it Figure 4 3 2 Open the drive sled handle by rotating it outward and toward th...

Page 57: ...Using a 2 Phillips screwdriver install the four mounting screws to secure the new drive to the drive sled as shown in Figure 4 5 Install the New Drive The nTier300 VTL automatically detects the drive...

Page 58: ...on push the handle inward and to the right until it locks in place An audible click indicates that the drive sled is locked into position Note The latch occasionally sticks in the open position If thi...

Page 59: ...e hardware operating systems networks and backup software packages Spectra Logic offers a worldwide on site service and maintenance structure refined over many years to provide timely professional ser...

Page 60: ...n a ticket using telephone e mail or the Spectra Logic Web site 1 Note the problem including what happened just before the failure occurred 2 Gather the information you will need to provide to Spectra...

Page 61: ...ship the component Domestic Returns Instructions Notes Ship the package to Spectra Logic Corporation ATTN RMA Number Suite B 5571 Arapahoe Avenue Boulder CO 80303 Make sure you write the RMA number on...

Page 62: ...her than Spectra Logic If any of the above conditions exist Spectra Logic reserves the right to repair the unit at the current fixed price of repair Warranty service may be acquired during the one yea...

Page 63: ...of SpectraGuard Service SpectraGuard Standard One year of SpectraGuard Standard service is included in the purchase of every nTier300 VTL SpectraGuard Standard is appropriate for customers who are ab...

Page 64: ...ware and firmware as they become available Online Support Customers have access to www spectralogic com support for the SpectraGuard knowledge base and all online documentation SpectraGuard Premier Sp...

Page 65: ...ved geographical area you may request approval The approval may take up to five business days Approval is dependent upon your site s proximity to a major metropolitan area Most on site service contrac...

Page 66: ...Appendix A Technical Support 66 Notes...

Page 67: ...The following table shows the RAID storage specifications for the nTier300 VTL Parameter Specification RAID Capacity a a The native capacity numbers refer to raw disk capacity RAID configuration and...

Page 68: ...ions One 10 GbE data port or one Fibre Channel or one SCSI a Gigabit Ethernet Parameter nTier300 VTL Chassis Shipping Container a b a Specifications are subject to change without notice b Includes uni...

Page 69: ...5 15P male connector to plug into an electrical outlet and a molded IEC 60320 C13 female connector to plug into the nTier300 VTL power supply 220 Volt AC Power Cord for Use in North America The criter...

Page 70: ...to connect to the nTier300 VTL power supply It must be a flexible HAR harmonized type H05VV F three conductor cord with minimum conductor size of 0 03 square inches 1 0 square millimeter Environmental...

Page 71: ...on the regulatory and safety standards that apply to the Spectra nTier300 VTL appliance See the following sections for detailed information on each EU Declaration of Conformity on page 72 FCC Notice...

Page 72: ...istics of information technology equipment EN 55024 1998 Information Technology Equipment Immunity Characteristics Limits and Methods of Measurement EN 61000 4 2 1995 A1 1998 A2 2001 Electrostatic Dis...

Page 73: ...u must be running your nTier300 VTL appliance on an uninterruptable power supply FCC Notice This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to...

Page 74: ...he WEEE directive This directive only applicable in European Union countries indicates that this product should not be disposed of with normal unsorted municipal waste Within participating European Un...

Page 75: ...data stored written to or retrieved read from a disk BlueScale Software available on Spectra nTier300 VTL appliance that supports nTier300 VTL configuration and monitoring bus A bus is a collection of...

Page 76: ...onfiguration Protocol A protocol for assigning dynamic IP addresses to devices on a network With dynamic addressing a device can have a different IP address every time it connects to the network In so...

Page 77: ...billion bits per second for use in LAN backbone systems 10 Gigabit Ethernet Provides transmission speeds of up to 10 billion bits per second 10 Gbps F Fibre Channel The ANSI standard that defines an...

Page 78: ...oved and replaced while the RAID array remains powered on and operational HTML HyperText Markup Language The document format used on the web Web pages are built with HTML tags codes embedded in the te...

Page 79: ...al drive A logical drive might be located on one or more physical drives LUN Logical Unit Number A unique identifier used by a SCSI device that enables it to address up to eight separate devices each...

Page 80: ...as controlling and allocating memory prioritizing system requests controlling input and output devices facilitating networking and managing files It also may provide a graphical user interface for hig...

Page 81: ...t make up a RAID array You can configure only one RAID level across each volume group Each volume group stores its own redundancy data The capacity of the volume group is the aggregate capacity of the...

Page 82: ...k into an interconnected but independent segment or domain in order to improve performance and security support ticket SpectraGuard opens support tickets to record problems experienced with your nTier...

Page 83: ...ntain event driven rarely used or archival data stored on tape See also HSM U USB Universal serial bus A plug and play hardware interface between a computer and add on devices such as audio players jo...

Page 84: ...ne or more volumes to a host W WWN World Wide Name specific to Fibre Channel A unique 48 bit or 64 bit number that identifies a connection or a set of connections to the network A WWN is assigned for...

Page 85: ...22 status on Overview page 45 to 47 unpacking 19 to 20 compliance EU 72 FCC 73 safety 74 WEEE 74 Component OK icon 42 component status messages 42 to 44 monitoring through Overview page 45 to 47 compo...

Page 86: ...tting gateway address 49 setting through web interface 48 to 49 viewing through Network page 48 K Knowledge Base accessing 4 for technical support 4 web address 4 L LEDs power button 13 power supply 1...

Page 87: ...icy 61 warranty policy 62 replacing drives 53 to 58 requirements for service 65 to 65 power 69 to 70 requirements installing the nTier300 VTL 17 resetting nTier300 VTL 50 returns RMA policy 61 warrant...

Page 88: ...e description 11 reboot or shut down the nTier300 VTL 50 W Warning icon 42 warnings AC power 3 high voltage 3 security certificate 39 weight 3 29 warranty 59 repair policy 62 standard service 63 web i...

Reviews: