130
Southwestern Industries, Inc.
TRAK
2
OP
M11 Installation, Maintenance, Service, & Part List Manual
Figure 6.15
Please also refer to drawing 27500-1 for a reference drawing.
To bleed air from the system, follow this procedure.
1.
Make sure all connection points are tight and no air can get into the system. If the connection
points are tight and not leaking but you notice oil leaking from the tool clamp cylinder, the
cylinder will need to be replaced.
2.
Make sure to fill the oil reservoir cap to the fill line. If the system has been leaking the oil level
will have dropped.
3.
Press the unclamp button on the front of the head a number of times over and over until you do
not see any more oil bubbles in the oil reservoir. The air should escape from the top of the oil
reservoir tank.
6.16 Programming Panel Replacement
See reference drawing 27648-2 for cable connections or section 5.4 of manual.
1.
Turn power off to the machine.
2.
Remove the 4 bolts that hold the programming panel in place.
3.
Remove the following 4 connectors: E-stop cable, com port cable, VGA cable and overlay power
cable. See section 5.4 for a diagram of these connections.
4.
Reconnect cables to new panel.
5.
Fasten panel with the 4 bolts you removed.
Summary of Contents for TRAK 2OP M11
Page 6: ...3 Southwestern Industries Inc TRAK 2 OP M11 Installation Maintenance Service Part List Manual...
Page 7: ...4 Southwestern Industries Inc TRAK 2 OP M11 Installation Maintenance Service Part List Manual...
Page 8: ...5 Southwestern Industries Inc TRAK 2 OP M11 Installation Maintenance Service Part List Manual...
Page 12: ...9 Southwestern Industries Inc TRAK 2 OP M11 Installation Maintenance Service Part List Manual...
Page 71: ...68 Southwestern Industries Inc TRAK 2 OP M11 Installation Maintenance Service Part List Manual...