6-126
HVR-Z1J/Z1U/Z1N/Z1E/Z1P/Z1C
4. COMPONENT OUTPUT Level Adjustment
(VC-367 Board)
Note1:
Perform this item in NTSC (60i) mode or PAL (50i) mode only
reguired.
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Y signal: Y signal terminal of
COMPONENT OUTPUT connector
(75
Ω
terminated)
PR signal: PR signal terminal of
COMPONENT OUTPUT connector
(75
Ω
terminated)
PB signal: PB signal terminal of
COMPONENT OUTPUT connector
(75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
82, 83, 84
Specified Value
Y level:
A = 1000
±
10mV
PR level:
B = 525
±
10mV
PB level:
C = 525
±
10mV
SYNC level: D = E = 300
±
10mV
Note:
When the component video signals are not outputted, connect the
SW terminal (Pin
q;
) of the COMPONENT OUTPUT connector to
GND.
Switch setting:
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
DISP OUTPUT (OTHERS menu) .................... LCD PANEL
NTSC (60i)/PAL (50i) ..... NTSC (60i) (HVR-Z1J/Z1U/Z1N)
PAL (50i) (HVR-Z1E/Z1P/Z1C)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
01
Set the data.
3
8
01
04
Set the data, and press PAUSE button.
4
0
10
00
Set the data.
5
Connect the oscilloscope to the
Y signal terminal.
6
C
82
Change the data and set the Y
level (A) to the specified value.
7
C
82
Press PAUSE button.
8
Check that the SYNC level (D)
and SYNC level (E) are satisfied
the specified value.
9
Connect the oscilloscope to the
PR signal terminal.
10
C
83
Change the data and set the PR
level (B) to the specified value.
11
C
83
Press PAUSE button.
12
Check that the SYNC level (D)
and SYNC level (E) are satisfied
the specified value.
13
Connect the oscilloscope to the
PB signal terminal.
14
C
84
Change the data and set the PB
level (C) to the specified value.
15
C
84
Press PAUSE button.
16
Check that the SYNC level (D)
and SYNC level (E) are satisfied
the specified value.
17
0
10
01
Set the data.
18
8
01
00
Set the data, and press PAUSE button.
Y signal
Fig. 6-3-7.
PR signal
Fig. 6-3-8.
PB signal
Fig. 6-3-9.
H
A
D
E
H
B
D
E
H
C
D
E
Order Page Address Data
Procedure
19
0
10
00
Set the data.
20
0
01
00
Set the data.
Ver. 1.7 2007. 10