6-43
HVR-Z1J/Z1U/Z1N/Z1E/Z1P/Z1C
19-2. White Balance Check ND 1
Subject
Clear chart
(HD color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.4 and 0.1
Measurement Point
Video terminal of
Display data of
AUDIO/VIDEO
page 1 (Note2)
jack
Measuring Instrument
NTSC or PAL
Adjustment remote
Vectorscope
commander
Specified Value 1
Fig. 6-1-15 (A)
Specified Value 2
Fig. 6-1-15 (B)
Specified Value 3
8000 to 8B80
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ........................................................................... 1
(Page: 6, Address: 9B, Bit4=1, Bit5=0)
3)
STEADY SHOT (CAMERA SET menu) ........................ OFF
4)
FOCUS .................................................................. MANUAL
5
ZOOM ........................................................................ LEVER
Fig. 6-1-15 (A).
Fig. 6-1-15 (B).
Checking method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “1”.
Indoor white balance check
2
Check that the lens is not
covered with either filter.
3
6
01
0F
Set the data, and press PAUSE
button.
4
6
C9
10
Set the data, and press PAUSE
button.
5
Check that the center of the
white luminance point is within
the circle shown Fig. 6-1-14 (A)
6
6
01
00
Set the data, and press PAUSE
button.
Outdoor white balance check
7
Place the C14 filter on the lens.
8
6
01
3F
Set the data, and press PAUSE
button.
9
6
C9
10
Set the data, and press PAUSE
button.
10
Check that the center of the
white luminance point is within
the circle shown Fig. 6-1-14 (B)
11
Remove the C14 filter.
12
6
01
00
Set the data, and press PAUSE
button.
LV data check
13
Place the ND filter 1.5
(1.0+0.1+0.4) on the lens.
14
6
01
23
Set the data, and press PAUSE
button.
15
0
03
06
Set the data.
16
1
Check that the display data
(Note2) satisfies the specified
value3.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
C9
00
Set the data, and press PAUSE
button.
3
0
03
00
Set the data.
4
Remove the ND filter.
5
Set ND FILTRE switch to
“OFF”.
R-Y
2mm
B-Y
2mm
R-Y
B-Y
0.5mm
1mm
3mm
3mm