6-49
HVR-Z1J/Z1U/Z1N/Z1E/Z1P/Z1C
22. Color Reproduction Check SD STD
γ
(NTSC (60i) & PAL (50i) modes)
Note:
Perform these adjustments of all in NTSC (60i) mode first, and
then perform these adjustments of all in PAL (50i) mode.
22-1. Color Reproduction Check
ND OFF SD STD
γ
Subject
Color bar chart
(HD color bar standard picture frame)
Measurement Point
NTSC or PAL vectorscope: Video
terminal of AUDIO/VIDEO jack (Note3)
Measuring Instrument
Oscilloscope: COMPONENT
connector
Specified Value
All color luminance points should
settle within each color reproduction
frame (SD STD
γ
). (Fig. 6-1-22.)
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3:
When using the vectorscope, disconnect the cable from the
COMPONENT connector.
Switch setting:
1)
REC FORMAT (IN/OUT REC menu) .............................. DV
(Page: 6, Address: 9B, Bit2=1)
2)
ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3)
STEADY SHOT (CAMERA SET menu) ........................ OFF
4)
FOCUS .................................................................. MANUAL
5)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Set REC FORMAT to “DV”.
2
Set ND FILTRE switch to
“OFF”.
3
0
01
01
Set the data.
4
6
01
4D
Set the data, and press PAUSE
button.
5
6
9D
Change the data and set the Y
signal level (A) to 90 IRE
(NTSC) or 88 IRE (PAL).
(Note4) (Fig. 6-1-21.)
6
6
9E
22
Set the data.
7
6
12
80
Set the data.
8
6
12
00
Set the data.
9
Check that the Y signal level (A)
is 90 IRE (NTSC) or 88 IRE
(PAL).
10
Check that each center of all
color luminance points is set in
each color reproduction frame.
Note4:
The Y signal terminal (Pin
1
) of the COMPONENT connector
must be terminated at 75
Ω
.
90 IRE = 630 mV, 88 IRE=616mV
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
9D
00
Set the data.
3
0
01
00
Set the data.
Fig. 6-1-21.
For SD STD
γ
mode
Fig. 6-1-22.
H
A
NTSC Burst position
PAL Burst position
Ver. 1.7 2007. 10