6-24
HVR-Z1J/Z1U/Z1N/Z1E/Z1P/Z1C
IC1107
1
4
8
5
VC-367 BOARD (SIDE A)
CD-522 BOARD (SIDE A)
IC104
R149
IC105
R150
IC106
R151
Fig. 6-1-6.
1.
Origin Oscillation Check (NTSC (60i) & PAL
(50i) modes) (VC-367 board)
Check the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Note1:
Origin oscillation frequency:
80.9090MHz ...... NTSC mode
80.1000MHz ...... PAL mode
Subject
Not required
Measurement Point
CD-522 board R149
(Pin
<
F1
of IC104)
or CD-522 board R150
(Pin
<
F1
of IC105)
or CD-522 board R151
(Pin
<
F1
of IC106)
or VC-367 board Pin
5
of IC1107
Measuring Instrument
Frequency counter
Specified Value
f=40454500
±
800Hz (NTSC)
f=40500000
±
800Hz (PAL)
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
POWER .................................................................. CAMERA
Checking method in NTSC (60i) mode:
1)
Set the NTSC (60i)/PAL (50i) switch to “NTSC (60i)”.
2)
Check that the frequency (f) satisfies the NTSC specified value.
Checking method in PAL (50i) mode:
1)
Set the NTSC (60i)/PAL (50i) switch to “PAL (50i)”.
2)
Check that the frequency (f) satisfies the PAL specified value.