6-124
HVR-Z1J/Z1U/Z1N/Z1E/Z1P/Z1C
1. S VIDEO OUT Y Level Adjustment (VC-367 Board)
Note1:
This item must be performed in both modes NTSC (60i) and PAL
(50i).
Note2:
< >: NTSC (60i) mode, [ ]: PAL (50i) mode
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Y signal terminal of S VIDEO jack
(75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
<25> [85]
Specified Value
A = 1000
±
14mV
Note3:
Disconnect the cable from the COMPONENT OUTPUT
connector.
Note4:
The data of page: 0, address: 10 must be “00”.
Switch setting:
NTSC (60i)/PAL (50i) (DB-018 board S201)
.................................................... <NTSC (60i)>, [PAL (50i)]
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
0C
02
Set the data, and press PAUSE
button.
3
Wait for 5 sec.
4
3
11
Check that bit5 of the data is
“1”. (Note4)
5
C
<25>
Change the data and set the Y
[85]
signal level (A) to the specified
value.
6
C
<25>
Press PAUSE button.
[85]
7
3
0C
00
Set the data, and press PAUSE
button.
8
0
01
00
Set the data.
Note5:
For the bit values, refer to “6-4. SERVICE MODE”, “4-3. 3. Bit
value discrimination”.
2. S VIDEO OUT Chroma Level Adjustment (VC-367 Board)
Note1:
This item must be performed in both modes NTSC (60i) and PAL
(50i).
Note2:
< >: NTSC (60i) mode, [ ]: PAL (50i) mode
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Chroma signal terminal of S VIDEO
jack (75
Ω
terminated)
External trigger: Y signal terminal of
S VIDEO jack
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
<26, 27> [86, 87]
Specified Value
Cr level:
A = 714
±
14mV (NTSC)
A = 700
±
14mV (PAL)
Cb level:
B = 714
±
14mV (NTSC)
B = 700
±
14mV (PAL)
Burst level: C = 286
±
6mV (NTSC)
C = 300
±
6mV (PAL)
Note3:
Disconnect the cable from the COMPONENT OUTPUT connector.
Note4:
The data of page: 0, address: 10 must be “00”..
Switch setting:
NTSC (60i)/PAL (50i) (DB-018 board S201)
..................................................... <NTSC (60i)>,[PAL (50i)]
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
0C
02
Set the data, and press PAUSE button.
3
Wait for 5 sec.
4
3
11
Check that bit5 of the data is
“1”. (Note4)
5
C
<26>
Change the data and set the Cr signal
[86]
level (A) to the specified value.
6
C
<26>
Press PAUSE button.
[86]
7
C
<27>
Change the data and set the Cb signal
[87]
level (B) to the specified value.
8
C
<27>
Press PAUSE button.
[87]
9
Check that the burst signal level
(C) is satisfied the specified value.
10
3
0C
00
Set the data, and press PAUSE button.
11
0
01
00
Set the data.
Note5:
For the bit values, refer to “6-4. SERVICE MODE”, “4-3. 3. Bit
value discrimination”.
H
A
H
C
A
0.28
µ
sec (NTSC)
0.23
µ
sec (PAL)
B
0.28
µ
sec (NTSC)
0.23
µ
sec (PAL)
Fig. 6-3-4.
Fig. 6-3-5.
Ver. 1.7 2007. 10