6-11
HVR-Z1J/Z1U/Z1N/Z1E/Z1P/Z1C
2. Modification of 8, C, 13, 18, 1C Page Data
If the 8, C, 13, 18, 1C page data has been initialized, change the
data of the “Fixed data-2” address shown in the following table by
manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the 8, C page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 13, 18, 1C page data, select page: 0, address:
10, and set data: 01.
After completing the modification of 13, 18, 1C page data,
reset the data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of 8, C, 13, 18, 1C Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
Version check of the mechanism control microprocessor:
(VC-367 board IC8801)
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
3
FF
The data shows the version of the
mechanism control
microprocessor.
30: Ver. 3.0 (MP3)
40: Ver. 4.0 (MP4)
50: Ver. 5.0 (MP5)
60: Ver. 6.0 (MP6)
70: Ver. 7.0 (MP7)
80: Ver. 8.0 (MP8)
1-2-2.
INITIALIZATION OF 8, C, 13, 18, 1C PAGE DATA
Note1:
When reading or writing the 8, C page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 13, 18, 1C page data, select page: 0,
address: 10, and set data: 01, then select 3, 8 or C page. The 13, 18
or 1C page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
NTSC model: HVR-Z1J/Z1U/Z1N
PAL model: HVR-Z1E/Z1P/Z1C
1. Initializing the 8, C, 13, 18, 1C Page Data
Note1:
If “Initializing the 8, C, 13, 18, 1C Page Data” is performed, all
data of the 8 page, C page, 13 page, 18 page and 1C page will be
initialized. (It is impossible to initialize a single page.)
Note2:
If the 8, C, 13, 18, 1C page data has been initialized, following
adjustments need to be performed again.
1) Modification of 8, C, 13, 18, 1C page data
2) Viewfinder system adjustments
3) LCD system adjustments
4) Serial No. input
5) Servo and RF system adjustments
6) Video system adjustments
Adjusting page
8
Adjusting Address
00 to FF
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
13
Adjusting Address
00 to FF
Adjusting page
18
Adjusting Address
00 to FF
Adjusting page
1C
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
3
81
00
Set the data.
4
3
80
0C
Set the data, and press PAUSE
button.
5
3
80
Check that the data changes to
“1C”.
6
Perform “Modification of 8, C,
13, 18, 1C Page Data”.
Ver. 1.7 2007. 10
The changed portions from
Ver. 1.6 are shown in blue.