6-35
HVR-Z1J/Z1U/Z1N/Z1E/Z1P/Z1C
13. Picture Frame Setting (NTSC (60i) & PAL (50i) modes)
Note1:
Perform these adjustments of all in NTSC (60i) mode first, and
then perform these adjustments of all in PAL (50i) mode.
When performing the following adjustments (except for “MAX
GAIN Adjustment”), set the picture frame to “HD color bar standard
picture frame”.
Subject
Color bar chart
(HD color bar standard picture frame)
(0.4m (PTB-1450) or 1.0m (PTB-450)
from the front of the lens)
Measurement Point
COMPONENT connector
Measuring Instrument
Oscilloscope and HD TV monitor
Specified Value
A=B, C=D, E=0, F=0
Note2:
The data of page: 0, address: 10 must be “00”
Note3:
When the component video signals are not output, connect the
SW terminal (Pin
q;
) of the COMPONENT connector to GND.
Switch setting:
1)
NTSC (60i)/PAL (50i) ........ NTSC (60i) (NTSC (60i) mode)
PAL (50i) (PAL (50i) mode)
2)
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
3)
ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
4)
FOCUS .................................................................. MANUAL
5)
ZOOM RING/LEVER ............................................... LEVER
6)
PICTURE PROFILE ........................................................ OFF
Setting method:
Order Page Address Data
Procedure
1
6
2C
11
Set the data.
2
6
90
Set the following data.
00 (PTB-1450), F4 (PTB-450)
3
6
91
Set the following data.
03 (PTB-1450), 02 (PTB-450)
4
6
92
Set the following data.
80 (PTB-1450), 5C (PTB-450)
5
6
93
Set the following data.
62 (PTB-1450), 43 (PTB-450)
6
6
01
79
Set the data, and press PAUSE
button.
7
Adjust the camera direction, and
set to the specified position.
8
Perform the following
adjustments. (Note4)
Note4:
When using the clear chart, remove the color bar chart from the
pattern box and insert a clear chart in its place. (Do not perform
zoom operations during this time.)
How to release the picture frame setting:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
2C
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
6
90
00
Set the data.
5
6
91
00
Set the data.
6
6
92
00
Set the data.
7
6
93
00
Set the data.
Check on the oscilloscope
1. Horizontal period
Fig. 6-1-10.
2. Vertical period
Fig. 6-1-11.
Check on the monitor TV (Underscanned mode)
Fig. 6-1-12.
A=B
C=D
A
B
C
D
H
E = 0 (msec), F = 0 (msec)
E
F
V
A=B
C=D
E = 0 (mm)
F = 0 (mm)
A
B
C
D
E
F
Color bar chart picture frame
Monitor TV picture frame
Ver. 1.7 2007. 10