6-38
HVR-Z1J/Z1U/Z1N/Z1E/Z1P/Z1C
16. LV Standard Data Input
(NTSC (60i) & PAL (50i) modes)
Note1:
Perform these adjustments of all in NTSC (60i) mode first, and
then perform these adjustments of all in PAL (50i) mode.
Adjust the normal coefficient of the light value.
Subject
Clear chart
(HD color bar standard picture frame)
Measurement Point
Display data of page 1 (Note4)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1A, 1B
Specified Value
0FE0 to 1020
Note2:
This adjustment should be carried out upon completion of “Auto
White Balance Standard Data Input”.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note5:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3)
STEADY SHOT (CAMERA SET menu) ........................ OFF
4)
FOCUS .................................................................. MANUAL
5)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Check the picture frame.
Refer to “10. Picture Frame
Setting”.)
2
0
01
01
Set the data.
3
6
30
01
Set the data.
4
6
C9
10
Set the data.
5
6
01
0D
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01”. (Note6)
7
0
03
1E
Set the data.
8
1
Check that the display data
(Note5) satisfies the specified
value. (Note7)
Note6:
The adjustment data will be automatically input to page: F, address:
1A, 1B.
Note7:
If it isn’t satisfied, repeat the adjustment again.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
30
00
Set the data.
3
6
C9
00
Set the data.
4
0
03
00
Set the data.
5
0
01
00
Set the data.
17. Auto White Balance Adjustment
(NTSC (60i) & PAL (50i) modes)
Note:
Perform these adjustments of all in NTSC (60i) mode first, and
then perform these adjustments of all in PAL (50i) mode.
17-1. Auto White Balance Adjustment ND OFF
Adjust to the proper auto white balance output data when the ND
filter switch is “OFF”.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(HD color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
Adjustment Address
3C to 3F, 40 to 43
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3)
FOCUS .................................................................. MANUAL
4)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the
lens.
2
0
01
01
Set the data.
3
F
3C
2B
Set the data, and press PAUSE
button.
4
F
3D
E0
Set the data, and press PAUSE
button.
5
F
3E
58
Set the data, and press PAUSE
button.
6
F
3F
78
Set the data, and press PAUSE
button.
7
6
01
83
Set the data, and press PAUSE
button.
8
6
01
81
Set the data, and press PAUSE
button.
9
6
02
Check that the data changes to
“01”. (Note3)
Note3:
The adjustment data will be automatically input to page: F, address:
40 to 43.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
3
Remove the C14 filter.
Ver. 1.7 2007. 10