6-28
HVR-Z1J/Z1U/Z1N/Z1E/Z1P/Z1C
5-2. Zoom Ring Adjustment (2)
The end sensor adjustment of the zoom ring is carried out semi-
automatically.
Subject
Not required
Measurement Point
Display data of page 1 (Note3)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
E8 to EB
Specified Value
Bit1 = 1, Bit2 = 1, Bit6 = 0 (Note3)
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3:
Displayed data of page 1 of the adjustment remote commander.
1 : Y Z : XX
Object data 2
Object data 1
When the specified value is satisfied. the object data 1 (Y) is “0”
to “3” or “8” to “B”, and the object data 2 (Z) is “6”, “7”, “E” or
“F”.
Switch setting:
NTSC (60i)/PAL (50i) ......................................... NTSC (60i)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
B5
Set the data, and press PAUSE
button.
3
Rotate the zoom ring to WIDE
end slowly.
4
Rotate the zoom ring to TELE
end slowly.
5
6
01
B7
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01”. (Note3)
7
0
03
28
Set the data.
8
1
Check that bit1, bit2 and bit6 of
the data satisfy the specified
value.
Note3:
The adjustment data will be automatically input to page: F, address:
E8 to EB.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.