5-22
BVP-500
BVP-500P
9.
Confirm that the carrier leakage does not observed at
portion C on the waveform monitor.
Specifications
: C = Minimum
(Waveform Monitor)
File Store:
1.
Set the DISPLAY switch/rear panel to MENU while
pushing up the MENU SELECT switch to ENTER.
2.
Execute the file store. Throw the MENU SELECT
switch to ENTER to execute.
MENU
: Reference File
PAGE
: Reference File (R1)
ITEM
: File Store
Resetting after Adjustment:
• TEST 1 button/MSU operation panel
→
OFF (Goes out)
• G button/rear panel
→
OFF
5-17. Flare Adjustment
Equipment
: Waveform monitor
Test Point
: MONITOR connector
Object
: Grayscale chart
Preparations:
• Connect the waveform monitor to the MONITOR
connector.
• KNEE OFF button/MSU operation panel
→
OFF (Lights)
• S650 (MONITOR SELECT)/IF-538 panel
→
VBS
• Shoot the grayscale chart so that the chart frame is
aligned with the underscanned monitor frame.
Iris of the lens
: A = 100
±
2 IRE (for NTSC)
A = 700
±
14 mV (for PAL)
(Waveform Monitor)
Adjustment Procedures:
1.
Adjust the auto white balance.
WHITE button/MSU operation panel
→
ON (Lights)
2.
Open the iris control of the lens by two stops against
the reference setup (corresponding to the above A).
3.
S650 (MONITOR SELECT)/IF-538 panel
→
VF
G button/rear panel
→
ON
4.
Select the 15 lines in the center of the monitor screen
by using the 15 LINE SELECT on the waveform
monitor.
(Waveform Monitor)
5-16. Gamma Correction Adjustment
5-17. Flare Adjustment
Line select