![Sony BVP-500 Maintenance Manual Download Page 58](http://html.mh-extra.com/html/sony/bvp-500/bvp-500_maintenance-manual_392023058.webp)
4-6
BVP-500
BVP-500P
VA
TEST
R GAIN
R
G GAIN
R
B
B GAIN
1
2
3
4
F
G
E
D
B
C
A
VA-163 BOARD (A SIDE)
CT200
RV200
CT300
CT400
RV400
RV300
4-3. VA Gain Adjustment
9.
Test Point
: TP72 (GND:TP71)/extension board
(extending VA-163)
Iris of the lens
: A = 125 mV (at F7.0 or more)
(Oscilloscope)
10. S650 (MONITOR SELECT)/IF-538 panel
→
VF
G button/rear panel
→
ON
11. Adjust the VA gain for G.
Test Point
: MONITOR connector
Adjustment Point
:
1
RV300 (G GAIN)/VA-163
panel
Specifications
: The levels A and B are shall be
equal when the TEST 2 button/
MSU operation panel is turned
on and off.
A = B
(Oscilloscope)
12. Test 2 button/MSU operation panel
→
OFF
13. Select the 15 lines in the center of monitor screen C by
using the 15 LINE SELECT on the waveform monitor.
14. Put the waveform monitor into the CHROMA mode.
15. S650 (MONITOR SELECT)/IF-538 panel
→
VBS
16.
Test Point
: MONITOR connector
Adjustment Point
:
1
RV200 (R GAIN)/VA-163
panel
1
RV400 (B GAIN)/VA-163
panel
Specifications
: Carrier leakage D = Minimum
(Waveform Monitor)
C
Resetting after Adjustment:
• S650/IF-538 panel
→
VBS
• G button/rear panel
→
OFF
Summary of Contents for BVP-500
Page 14: ...1 6 BVP 500 BVP 500P 1 3 Outside Dimentions 1 3 Outside Dimentions Unit mm ...
Page 22: ...1 14 BVP 500 BVP 500P ...
Page 120: ......