5-6
BVP-500
BVP-500P
5-3. CCU Y Adjustment
Equipment
: Oscilloscope
Test Point
: TP3(Y)/DA-88 panel
Preparations:
• S650 (MONITOR SELECT)/IF-538 panel
→
VBS
Adjustment Procedures:
1.
Set the DISPLAY switch/rear panel to MENU while
pushing up the MENU SELECT switch to ENTER.
2.
Set the menu as follows.
MENU
: System config
PAGE
: Y/Chroma (S2)
ITEM
: CB
→
On
3.
Set the menu as follows and adjust the Y sync using
the MENU SELECT knob/switch.
Adjustment Point
:
MENU
: System config
PAGE
: Y/Chroma (S2)
ITEM
: Y SYNC
Specifications
: A = 303
±
2 mV (for NTSC)
A = 300
±
2 mV (for PAL)
4.
Set the menu as follows and adjust the Y video using
the MENU SELECT knob/switch.
Adjustment Point
:
MENU
: System config
PAGE
: Y/Chroma (S2)
ITEM
: Y Video
Specifications
: B = 700
±
2 mV
(For NTSC)
(For PAL)
(20MHz B/W LIMIT
→
ON)
File Store:
Execute the file store. Throw the MENU SELECT switch
to ENTER to execute.
MENU
: Triming File
PAGE
: Triming File (T1)
ITEM
: File Store
5-3. CCU Y Adjustment
Summary of Contents for BVP-500