3-17
BVP-500
BVP-500P
Page
Ver.
Item
Settings
Contents
OTHERS 1
FILTER,WHT MEM
[ON]
, OFF
Does not function in the unit. (The setting change becomes invalid.)
NTSC ENC
[WIDE]
, NRW
Sets the band width of the Q signal for the NTSC color encoder.
ROTARY
[STD]
, RVS
Selects the mode of MENU SELECT knob as turned clockwise.
STD : Cursor moves downwards and a numeric value increases.
RVS : Cursor moves upwards and a numeric value decreases.
OWN CALL
R, F&R , OFF
Selects whether TALLY lamps are lit corresponding to the
CALL button on rear panel pressed, or not. Or selects which TALLY
lamps are lit when the CALL button is pressed.
(This setting is valid in connection with CCU. When the standalone unit is
installed and MSU/RCP is not connected to the camera, it is always set to OFF.)
R
: Red TALLY lamps of VF are lit.
R&F : Red TALLY lamps of VF and UP TALLY lamps of VF and camera are lit.
OFF : No TALLY lamp is lit corresponding to the CALL button.
CENTER H POS –20 to 20 (
[XX]
)
Shifts horizontally the location of the center marker on the screen.
20 (right)
↔
–20 (left)
CENTER V POS –20 to 20 (
[XX]
)
Shifts vertically the location of the center marker on the screen.
20 (up)
↔
–20 (down)
LENS VTR S/S
TALK,
[RET2]
Selects the mode of VTR S/S SW of the lens.
TALK : VTR S/S SW functions as INCOM TALK SW (momentary).
RET2 : VTR S/S SW functions as RET2 SW.
VF ? DISPLAY
[ON]
, OFF
Turns on and off the indication of ? mark at the top-right of the VF screen with the
DISP switch set to ON when the self-diagnosis result is NG (no good) and so on.
PinP RET RVS
[RVS1]
, RVS 2, OFF
Selects the indication mode of VF display in PinP mode.
Setting RET 1
Large screen
Small screen
(or 2, 3) SW
RVS 1
ON
RET 1 (2, 3) video
Camera output
OFF
Camera output
The last RET video selected
RVS 2
ON
RET 1 (2, 3) video
Camera output
OFF
Camera output is displayed on the whole screen.
(Small screen is not displayed.)
OFF
ON
Camera output
RET 1 (2, 3) video
OFF
Camera output is displayed on the whole screen.
(Small screen is not displayed.)
*
To output RET 3 video signal, press RET 1 and 2 switches at the same time.
OTHERS 2
F TALLY RVS
[ON]
, OFF
Selects the operation mode of TALLY lamps corresponding to a CALL button
pressed when a TALLY signal is input to the camera from CCU or VTR.
ON : Red TALLY lamps of VF and UP TALLY lamps of VF and camera go out.
OFF : Red TALLY lamps of VF alone go out.
1.07
BLK GAM
[ON]
, OFF
ON : Inhibits the black gamma adjustment and on/off function from the
INHIBIT
MSU or Paint manu.
OFF: Enables the above operation.
1.10
CHAR CAM No.
1,2,3 , A,B,C
Selects the indication mode of the camera number set by the CAMERA
No. page of Operation menu.
1,2,3 : Indicates in numerics.
A,B,C : Indicates camera numbers 1 to 27 in alphabetical order of A to Z.
(When connecting 28 or more cameras, select “1,2,3”.)
1.10
WHT SETUP
[AWB]
, LEVEL
AWB
: After executing the LEVEL AUTO, white balance adjustment
MODE
data returns to the value before execution.
LEVEL : After executing the LEVEL AUTO, white balance adjustment
data changes to the value after the white balance is adjusted
using TEST 2 signal.
1.10
AW SHADING
[RGB]
, RB ONLY
RGB
: When automatically adjusting the white balance, R, G, and
MODE
B signal waveforms are all flattened.
RB ONLY : When automatically adjusting the white balance, R and B
signal waveforms are flattened.
3-1. Setup Menu