4-1-2. Notes on Adjustment
• All measuring equipment shall be calibrated.
• Also the alignment for the OHB-400/500/500WS (or
their PAL version), CCU-700/700P/700A/700AP, and
MSU-700 shall be completed.
• To connect each equipment, refer to Section 4-1-4.
• As for initial settings before beginning adjustment, refer
to Section 4-1-5.
• Be sure to turn off the power switch on the power
assembly of the camera before disconnecting the printed
circuit boards.
n
Allow for about ten seconds until the unit is energized
when turning this switch off and then on momentarily.
• About ten-minute warm-up time is allowed before
beginning adjustment.
• When using the camera as 16:9 mode together with the
OHB-500WS/500WSP, use the specified grayscale chart
(J-6394-080-A).
• Paste a black colored velvets (around 3
×
3 cm) to both
sides of the white portion in the center of the grayscale
chart.
(For more details, consult your Sony service representa-
tive.)
4-1-3. Description of Setup Menu
A part of adjustments given in this section uses the setup
menu. The setup menu consists of the following menus.
Besides there is a TOP menu indicating the entire configu-
ration of menu items.
Operation
Paint
Maintenance
Reference File
Triming File
System config
To display all of the menus, switch setting of the AT-95
board is required. And for details on the setup menu, refer
to Section 3.
In this manual, describes the setup menu operation as
follows.
Title of the selected page (top right corner display)
For reference:
When Paint
→
Skin Detail is selected:
MENU
: Paint
PAGE
: Skin Detail (P4)
Displaying Setup Menu
1.
Power on the CCU and MSU.
2.
Set the internal switches of the AT-95 board as
follows.
S1-1
→
ON
S1-2
→
OFF
S1-3
→
ON
S1-4
→
OFF
3.
DISPLAY switch/rear panel
→
OFF
4.
POWER switch/camera power assembly
→
ON
5.
Set the DISPLAY switch/rear panel to MENU (from
OFF) while pushing up the MENU SELECT switch to
ENTER. (TOP menu will be displayed.)
n
If the power switch is turned off once, perform the above
operations again to display the setup menu (steps 3 to 5).
How to change the setting values
To enter or cancel the setting value of items, which can be
changed by turning the MENU SELECT knob, proceed as
follows.
To enter the setting value;
Press the MENU SELECT switch to ENTER.
To cancel the setting value;
Before pressing the MENU SELECT switch to ENTER,
press it to CANCEL. The original setting is restored.
After pressing the MENU SELECT switch to ENTER, the
setting can not be canceled.
File Store
If the adjustments in this section are suspended or the unit
is powered off to extend a printed circuit board and so on,
be sure to execute the FILE STORE before being powered
off. (Refer to section 4-20.)
4-1. Preparation