![Sony BVP-500 Maintenance Manual Download Page 90](http://html.mh-extra.com/html/sony/bvp-500/bvp-500_maintenance-manual_392023090.webp)
5-16
BVP-500
BVP-500P
12. Test 2 bottun/MSU operation panel
→
OFF
13. Select the 15 lines in the center of monitor screen C by
using the 15 LINE SELECT on the waveform monitor.
14. Put the waveform monitor into the CHROMA mode.
15. S650 (MONITOR SELECT)/IF-538 panel
→
VBS
16.
Test Point
: MONITOR connector
Adjustment Point
:
1
RV200 (R GAIN)/VA-163
panel
1
RV400 (B GAIN)/VA-163
panel
Specifications
: Carrier leakage D = Minimum
(Waveform Monitor)
Resetting after Adjustment:
• S650/IF-538 panel
→
VBS
• G button/rear panel
→
OFF
5-11. VA Gain Adjustment
VA
TEST
R GAIN
R
G GAIN
R
B
B GAIN
1
2
3
4
F
G
E
D
B
C
A
VA-163 BOARD (A SIDE)
CT200
RV200
CT300
CT400
RV400
RV300
C