5-9
DNW-7/90/90WS
A
H
V
A
5-12. H/V Ratio Adjustment
Preparation
.
On the setting menu, set as follows.
PAGE
: FUNCTION 1/2
ITEM
: DETAIL
→
ON
ITEM
: TEST OUT
→
ENC
.
OUTPUT/DCC switch (inside panel)
→
CAM/ON
.
Shoot a gray-scale chart in the full underscan’s picture
frame.
Setting point
:
1
Lens IRIS
Spec.
: A = 100
±
2 IRE (NTSC)
A = 700
±
14 mV (PAL)
Adjustment procedure
Equipment
: Black and white monitor
Test point
: TEST OUT connector
1.
On the setting menu, adjust as follows.
PAGE
: LEVEL 1
ITEM
: V DTL LEVEL
Spec.
: Adjust so that the H and V detail amounts
which are added are equivalent.
5-12. H/V Ratio Adjustment
5-13. Detail Level Adjustment
5-13. Detail Level Adjustment
Note
.
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
.
On the setting menu, set as follows.
PAGE
: FUNCTION 1/2
ITEM
: DETAIL
→
ON
ITEM
: TEST OUT
→
ENC
.
Shoot a gray-scale chart in the full underscan’s picture
frame.
Setting point
:
1
Lens IRIS
Spec.
: A = 80
±
2 IRE (NTSC)
A = 560
±
14 mV (PAL)
Adjustment procedure
Test point : TEST OUT connector
1.
On the setting menu, adjust as follows.
PAGE
: LEVEL 1
ITEM
: DETAIL LEVEL (Factory setting : 0)
Spec.
: Set to the detail signal which is added to
each step in the gray-scale chart.