3-11
DNW-7/90/90WS
Viewfinder screen (Factory default setting)
Description
* W-SHAD._R *
H SAW
: 0
H PARA
: 0
V SAW
: 0
........... Sets the manual white shading correction amount of R signal.
V PARA
: 0
H SAW (EXT)
: 0
H PARA (EXT)
: 0
V SAW (EXT)
: 0
........... Sets the manual white shading correction amount of R signal during the
extender mode.
V PARA (EXT)
: 0
SHAD COMP
: ON
........... Sets whether to activate the shading correction on R signal.
TEST OUT
: ENC
........... Sets the type of the video signal output from the TEST OUT connector.
n
Same as TEST OUT item of the “FUNCTION 1/2” page.
* W-SHAD._B *
H SAW
: 0
H PARA
: 0
V SAW
: 0
........... Sets the manual white shading correction amount of B signal.
V PARA
: 0
H SAW (EXT)
: 0
H PARA (EXT)
: 0
V SAW (EXT)
: 0
........... Sets the manual white shading correction amount of B signal during the
extender mode.
V PARA (EXT)
: 0
SHAD COMP
: ON
........... Sets whether to activate the shading correction on B signal.
TEST OUT
: ENC
........... Sets the type of the video signal output from the TEST OUT connector.
n
Same as TEST OUT item of the “FUNCTION 1/2” page.
* B-SHAD._G *
H SAW
: 0
H PARA
: 0
V SAW
: 0
........... Sets the manual black shading correction amount of G signal.
V PARA
: 0
SHAD COMP
: ON
........... Sets whether to activate the shading correction on G signal.
TEST OUT
: ENC
........... Sets the type of the video signal output from the TEST OUT connector.
n
Same as TEST OUT item of the “FUNCTION 1/2” page.
3-1. Setup Menu