5-8
DNW-7/90/90WS
A
A
5-10. Crispening Adjustment
Preparation
.
On the setting menu, set as follows.
PAGE
: FUNCTION 1/2
ITEM
: DETAIL
→
ON
.
OUTPUT/DCC switch (inside panel)
→
CAM/ON
.
Shoot a gray-scale chart in the full underscan’s picture
frame.
Setting point
:
1
Lens IRIS
Spec.
: A = 100
±
2 IRE (NTSC)
A = 700
±
14 mV (PAL)
Adjustment procedure
Equipment
: Black and white monitor
Test point
: TEST OUT connector
1.
On the setting menu, adjust as follows.
PAGE
: LEVEL 1
ITEM
: CRISPENING
Spec.
: Reduce the noise on the screen to a permis-
sible level.
5-10. Crispening Adjustment
5-11. Level Depandent Adjustment
B
5-11. Level Depandent Adjustment
Preparation
.
On the setting menu, set as follows.
PAGE
: FUNCTION 1/2
ITEM
: DETAIL
→
ON
ITEM
: TEST OUT
→
ENC
.
OUTPUT/DCC switch (inside panel)
→
CAM/ON
.
Shoot a gray-scale chart in the full underscan’s picture
frame.
Setting point
:
1
Lens IRIS
Spec.
: A = 100
±
2 IRE (NTSC)
A = 700
±
14 mV (PAL)
Adjustment procedure
Test point : TEST OUT connector
1.
On the setting menu, adjust as follows.
PAGE
: LEVEL 1
ITEM
: LEVEL DEPEND
Spec.
: Eliminate the detail signal from portion B.
Note
.
After this adjustment, be sure to perform 5-12. H/V
Ratio Adjustment, and 5-13. Detail Level Adjustment, in
that order.