1-23
DNW-7/90/90WS
1
2
3
4
5
F
E
D
C
A
DCP-31/1 A Side
S2
S1
S4
B
6
1-9-7. DCP-31/1 Board
Switches
Ref. No.
Name
Description
Factory setting
S1
ENG Disable Select
ON : Disables
OFF
OFF : Enables
S2
Character Select
Selects whether to display the character
2
on the viewfinder and TEST OUT connector.
1: Both viewfinder and TEST OUT connector
2: Viewfinder only
3: TEST OUT connector only
(For the character to be displayed on neither
the viewfinder nor TEST OUT connector,
set off the DISPLAY switch of the viewfinder.)
S4-1
_
Factory use
OFF
S4-2
Remote Connector
ON : Connects except RM-P9 and VA-DN1.
OFF
OFF : Connects RM-P9 or VA-DN1.
S4-3
VF CAM Select
ON : Outputs the camera signal on the viewfinder
OFF
when the OUTPUT switch is set BARS.
OFF : Outputs the color bars signal on the viewfinder
when the OUTPUT switch is set BARS.
S4-4
CAM Mode
OFF : Uses the VTR START button as the INCOM
OFF
TALK ON button.
ON : Uses the VTR START button as the RET 2
button.
(When S4-4 is set ON, use the VTR SAVE/STBY
switch as the INCOM TALK ON button.)
S4-5 to 7
_
Not used
OFF
S4-8
Data reset
ON : Resets in the setting menu
OFF
when the power is turn on.
OFF : Uses in normal times.
1-9. Switch/Slit Land Settings on the Boards
1-9-7. DCP-31/1 Board