5-4
DNW-7/90/90WS
5-5. White Shading Adjustment
Preparation
.
Lens IRIS
→
AUTO
.
Shoot a fully occupied white area of pattern box in the
underscan’s picture frame.
.
Waveform monitor setting
LUM mode
VOLT FULL SCALE range
→
0.5
Adjustment procedure
Test point : TEST OUT connector
1.
On the setting menu, set as follows.
PAGE
: W-SHAD_G
ITEM
: TEST OUT
→
G
2.
Make the waveform to flat by UP and/or DOWN
button on the inside panel according to the table
below.
3.
Adjust the shading for R and B channels in the same
way.
TEST OUT
H SAW
V SAW
H PARA
V PARA
G W-SHAD_G
W-SHAD_G
W-SHAD_G
W-SHAD_G
W-SHAD_G
TEST OUT
→
G H SAW
V SAW
H PARA
V PARA
R W-SHAD_R
W-SHAD_R
W-SHAD_R
W-SHAD_R
W-SHAD_R
TEST OUT
→
R H SAW
V SAW
H PARA
V PARA
B W-SHAD_B
W-SHAD_B
W-SHAD_B
W-SHAD_B
W-SHAD_B
TEST OUT
→
B H SAW
V SAW
H PARA
V PARA
4. Set the lens to EXTENDER and adjust in the same way.
TEST OUT
H SAW
V SAW
H PARA
V PARA
G W-SHAD_G
W-SHAD_G
W-SHAD_G
W-SHAD_G
W-SHAD_G
TEST OUT
→
G H SAW
V SAW
H PARA
V PARA
(EXT)
(EXT)
(EXT)
(EXT)
R W-SHAD_R
W-SHAD_R
W-SHAD_R
W-SHAD_R
W-SHAD_R
TEST OUT
→
R H SAW
V SAW
H PARA
V PARA
(EXT)
(EXT)
(EXT)
(EXT)
B W-SHAD_B
W-SHAD_B
W-SHAD_B
W-SHAD_B
W-SHAD_B
TEST OUT
→
B H SAW
V SAW
H PARA
V PARA
(EXT)
(EXT)
(EXT)
(EXT)
5-5. White Shading Adjustment
(H SAW)
(H PARA)
(H SAW)
(H PARA)
Setting after adjustment
.
On the setting menu, set as follows.
PAGE
: W-SHAD_B
ITEM
: TEST OUT
→
ENC