5-2
DNW-7/90/90WS
5-2. ENC Level Adjustment
Preparation
.
OUTPUT/DCC switch (inside panel)
→
BARS
.
On the setting menu, set as follows.
PAGE
: LEVEL 7
ITEM
: TEST OUT
→
ENC
Adjustment procedure
Equipment
:Waveform monitor
Test point
:VIDEO OUT connector
1. On the setting menu, adjust as follows.
PAGE
: LEVEL 5
ITEM
: ENC SYNC LEVEL
Spec.
: A = 40
±
1 IRE (NTSC)
A = 300
±
7 mV (PAL)
2. On the setting menu, adjust as follows.
PAGE
: LEVEL 5
ITEM
: ENC SETUP LEVEL
Spec.
: B = 7.5
±
0.5 IRE (NTSC)
B = 0
±
3 mV (PAL)
3. On the setting menu, adjust as follows.
PAGE
: LEVEL 5
ITEM
: ENC Y LEVEL
Spec.
: C = 100
±
2 IRE (NTSC)
C = 700
±
14 mV (PAL)
5-2. ENC Level Adjustment
5-3. TEST OUT Adjustment
5-3. TEST OUT Adjustment
Preparation
.
OUTPUT/DCC switch (inside panel)
→
BARS
.
On the setting menu, set as follows.
PAGE
: LEVEL 7
ITEM
: TEST OUT
→
R, G or B
Adjustment procedure
Test point
: TEST OUT connector
1. On the setting menu, adjust as follows.
PAGE
: LEVEL 5
ITEM
: RGB SYNC LEVEL
Spec.
: A = 40
±
2 IRE (NTSC)
A = 300
±
14 mV (PAL)
2. On the setting menu, adjust as follows.
PAGE
: LEVEL 5
ITEM
: RGB SETUP LEVEL
Spec.
: B = 7.5
±
0.5 IRE (NTSC)
B = 0
±
3 mV (PAL)
3. On the setting menu, adjust as follows.
PAGE
: LEVEL 5
ITEM
: RGB Y LEVEL
Spec.
: C = 100
±
2 IRE (NTSC)
C = 700
±
14 mV (PAL)
Setting after adjustment
.
On the setting menu, set as follows.
PAGE
: LEVEL 7
ITEM
: TEST OUT
→
ENC
C
R
A
B
C
R
PAL
NTSC
A
B
C
B
A
C
B
A
PAL
NTSC