6-13
DNW-7/90/90WS
6-18. Skin Tone Adjustment
Note
.
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
.
On the setting menu, set as follows.
PAGE
: LEVEL 2
ITEM
: SKIN TONE DTL
→
ON
ITEM
: SKIN TONE IND.
→
ON
.
Shoot a person’s face.
Adjustment procedure
Test point: TEST OUT, VIDEO OUT connector
1.
On the setting menu, set as follows.
PAGE
: LEVEL 2
ITEM
: SKIN TONE DET
→
ON
2.
Shoot a person’s face in the central of the viewfinder.
3.
Push the rotary switch (front panel).
(Display the detect area in zebra pattern.)
4.
Perform the adjustment in this step, if neccessary.
On the setting menu, adjust as follows.
PAGE
: LEVEL 2
ITEM
: X : Component of red (center)
Y : Component of blue (center)
dX : Component of red (range)
dY : Component of blue (range)
Display the skin detail detect area in zebra pattern.
Adjust zebra pattern displays only normal area.
5.
On the setting menu, adjust as follows.
PAGE
: LEVEL 2
ITEM
: SUPPRESS LEVEL (Factory setting: 0)
Spec.
: Set the level to the desired detail level.
Setting after adjustment
PAGE
: LEVEL 2
ITEM
: SKIN TONE DTL
→
OFF
ITEM
: SKIN TONE IND.
→
OFF
ITEM
: SKIN TONE DET
→
OFF
6-18. Skin Tone Adjustment