6-5
DNW-7/90/90WS
6-5. White Shading Adjustment
16:9 mode
Preparation
.
Lens IRIS
→
AUTO
.
Shoot a fully occupied white area of pattern box in the
underscan’s picture frame.
.
Waveform monitor setting
LUM mode
VOLT FULL SCALE range
→
0.5
Adjustment procedure
Test point: TEST OUT connector
1.
On the setting menu, set as follows.
PAGE
: W-SHAD_G
ITEM
: TEST OUT
→
G
2.
Make the waveform to flat by UP and/or DOWN button
on the inside panel according to the table below.
3.
Adjust the shading for R and B channels in the same way.
TEST OUT
H SAW
V SAW
H PARA
V PARA
G
W-SHAD_G
W-SHAD_G
W-SHAD_G
W-SHAD_G
W-SHAD_G
TEST OUT
→
G
H SAW
V SAW
H PARA
V PARA
R
W-SHAD_R
W-SHAD_R
W-SHAD_R
W-SHAD_R
W-SHAD_R
TEST OUT
→
R
H SAW
V SAW
H PARA
V PARA
B
W-SHAD_B
W-SHAD_B
W-SHAD_B
W-SHAD_B
W-SHAD_B
TEST OUT
→
B
H SAW
V SAW
H PARA
V PARA
4.
Set the lens to EXTENDER and adjust in the same way.
TEST OUT
H SAW
V SAW
H PARA
V PARA
G
W-SHAD_G
W-SHAD_G
W-SHAD_G
W-SHAD_G
W-SHAD_G
TEST OUT
→
G
H SAW
V SAW
H PARA
V PARA
(EXT)
(EXT)
(EXT)
(EXT)
R
W-SHAD_R
W-SHAD_R
W-SHAD_R
W-SHAD_R
W-SHAD_R
TEST OUT
→
R
H SAW
V SAW
H PARA
V PARA
(EXT)
(EXT)
(EXT)
(EXT)
B
W-SHAD_B
W-SHAD_B
W-SHAD_B
W-SHAD_B
W-SHAD_B
TEST OUT
→
B
H SAW
V SAW
H PARA
V PARA
(EXT)
(EXT)
(EXT)
(EXT)
Setting after adjustment
.
On the setting menu, set as follows.
PAGE
: W-SHAD_B
ITEM
: TEST OUT
→
ENC
(H SAW)
(H PARA)
(H SAW)
(H PARA)
6-5. White Shading Adjustment