42
but it was not enough to supply the demand so
the storage system only discharged enough to
fulfill the remainder (926W). We can see this same
behavior at point 2b when the system discharged
just enough to cover what the solar could not.
Direct access to the storage unit
The end user can gain direct access to the
sonnen eco Dashboard to view, and make changes
to, some system settings. To log in:
• Ensure you are using a device that can be
connected to the Internet (computer, laptop,
smart tablet, etc.)
• Verify that the device is on the same network
as the storage unit.
• Open a web browser (Chrome, Internet
Explorer, etc.)
1. Identify storage unit
▶
Navigate to this URL:
https://find-my.sonnen-batterie.com
This website will list all of the units on the
network.
▶
Identify the system you want to view
▶
Select the “Configure” button.
Fig. 87 Storage unit configure
▶
Log into the storage unit
▶
Dashboard
0
Fig. 88 Storage unit dashboard
The dashboard provides an informative overview
of the energy flow in the system to include the
solar production, the home consumption (loads
that are turned on in the home), the solar feed-in
to the grid (if any) and the grid power going into
the home. Battery state of charge (SOC) and any
power provided by the battery or power used to
charge the battery will also be displayed.
In this example, the solar production
(2,800W) is enough to power the loads in the
house (1800W) and export into the grid (1000W).
The yellow arrows show solar production flow. If,
for example, the home consumption increased to
3500W, then the arrow connecting the grid to
the sonnen would change direction towards the
sonnen unit and the description would change
from Feed-In to Consumption and the numeric
value would then read 700W.
Charge power represents the amount of
power that is currently being used to charge the
batteries. This source could be either the grid or
the solar. Discharge power is the amount of power
the storage system is sending to the home from
the batteries.
The green state of charge indicator will
change based on how full the battery bank is.
Fig. 89 Operating mode settings
Installer