38
Digital interface
Internet portal
The eco Gen 3.1 must connect to sonnen’s servers
to enable control of the storage system via the
Web portal and smart-phone app. This connection
is protected by industry-standard security against
unauthorized access. Sonnen and service partners
will only access the storage system for maintenance
and monitoring.
An anonymized evaluation of log data enables
further improvements and monitoring of hardware
and software.
Establish connection to the Internet
▶
Connect the storage system’s Ethernet cable to
your router.
▶
Make sure your router acts as a DHCP server
and configures newly connected network
devices automatically.
▶
Ensure the following outbound TCP and UDP
ports are permitted for the following services in
the router:
The listed ports are generally pre-
configured on the routers.
TCP Port
Service
22
SecureShell (ssh)
37
Time Server (ntp)
80
Online Check (http)
222
VPN (Server connection, ssl)
232
VPN (backup)
443
App control (https)
UDP Port
1196
(Server connection, ssl)
Table 4 Required open ports for storage system
The storage system connects automatically with
the Internet. There are no further steps required.
Internet portal
You can observe real-time and historical data
regarding your storage system via the Internet
portal.
▶
Log in to the portal
1. Type the following address to your Internet
browser:
https://my.sonnen-batterie.com/
The following login window will appear:
Fig. 78 Login window
▶
Enter the login information that you received
with your delivery. This is not the same login
used for direct access to the storage unit
parameters. The user name should start
with “psb” followed by a number: example:
psb65006
Summary of Contents for eco 10
Page 2: ...Page intentionally left blank ...
Page 4: ...Page intentionally left blank ...
Page 8: ...Page intentionally left blank ...
Page 58: ...o Part No 28058 Rev 6 ...