5. Additional upstream renewable source
production meter (rare)
6. Additional downstream renewable
source production meter (rare)
▶
Press "Continue".
11. Provide information about owner
Fig. 75 Inputting owner information
▶
Enter the owner's information.
▶
Press "Continue".
12. Provide information about installer
Fig. 76 Providing information about installer
▶
Input information about the installer.
▶
Check the confirmation box.
▶
Press "Continue".
13. Select Operating Mode
Fig. 77 Selecting Operating Mode
▶
Select the desired operating mode. Your
choices are:
• Manual: Charge and discharge the unit
manually
• Backup power: Use the storage unit to provide
power when the grid is unavailable
• Self-consumption: Use stored energy when
solar production is less than household
consumption
• Time of Use: Use stored energy only during
specified high-tariff times.
▶
Check the confirmation box.
▶
Press "Launch my sonnen Batterie."
▶
The session user will be logged out.
14. Set back-up buffer
▶
Log back in using the same credentials
Account:
Installer
Password:
Sonnen@Installer2016
▶
Click on "Settings" tab
▶
Click "Back-up buffer"
▶
Adjust the back-up buffer to the desired value.
The factory default value is 10% but a higher
value may be needed if more reliable and longer
lasting backup power is desired during grid
outages.
15. Verify CT configuration
▶
Without the PV system connected, use a multi-
meter, measure the current over CT 1 and CT2
wires.