Installation
26
Installation manual
thermi
nator
II touch
5.9.7
Service
The intermediate pellet store and its components are maintenance-free.
5.9.8
Settings in the SOLARFOCUS boiler control unit
Attention!
When commissioning the intermediate pellet store 110L, adjust the parameters in the screen below
as specified. Failure to observe this will lead to malfunction.
Make the following selection.
Fig. 5-10_01-114-02
5.10 Ash pan
5-11_001
Mount 2 x handles
1
with cylinder head screw
2
and nut
3
on the ash pan
4
.
Use ash pan only during boiler cleaning, never
place permanently in the combustion chamber.
5.11 Fuel chute
5-12_001AJ
Adjust the inclination of the fuel chute mounted in
the filling chamber (with hex bolts
1
) so that the
fuel is conveyed onto the middle of the stainless
steel combustion grate.
=
=