Installation
Installation manual
thermi
nator
II touch
17
5.3 Adjustable feet
5-1_005
Screw 4 x levelling feet (SW16)
1
into the
bottom plate of the boiler.
Align the boiler horizontally.
5.4 Mounting the hot air fan
The hot air fan can be mounted on the left or right side of the boiler (pre-wired on the left side).
Dual fuel boiler: With simultaneous use of
- Item
Intermediate pellet store 110 litre
(to be mounted on the left) and
- Item
Automatic switchover from log wood to pellets
(=shaker motor)
it is recommended to mount the hot air fan on the left.
If, when mounting the
intermediate pellet store 110 litre
, the hot air fan is mount-
ed on the left side of the boiler, then do not mount the fan cover (housing).
5-1_001-001BL-iAL
Separate the perforated section
1
from the side
cladding, e.g. using wire cutters.
Release the two M6 (WAF10) nuts
2
and remove
the blanking flange plate
3
and seal
4
.