Installation
24
Installation manual
thermi
nator
II touch
5.9.6
Installation sequence
Tools required:
Bit TX15 / TX20 ♦ Side cutter ♦ Wrench SW 7/12/17 ♦ Snap-off blade knife
5-3_001
Open side cladding
Boiler thermi
nator
II touch must be fully set up and
aligned.
The intermediate pellet store can only be installed
on the left side of the boiler. Mount the shaker mo-
tor
(optional item
Automatic switchover of log wood to pellets
)
on the right side of the boiler for better accessibility!
Separate the pre-punched part from side cladding
(using wire cutters).
Cut out the insulation behind the side cladding.
5-4_002
Removing the flange plate
Release 4 hex nuts M10 (SW17)
1
and remove the
flange plate
2
.
5-5_004
Install the feeder unit
If the vessel has an existing shaker motor (Item
Automatic switchover unit from logs to pellets
):
BEFORE installing the feeder unit, permanent-
ly remove the cover (housing) of the shaker
motor.
Ideally, however, the shaker motor is located
on the right side of the boiler.
Insert feeder unit
1
incl. flange seal
2
onto the thread-
ed bolts and fasten with 4 x hex nuts.
Route the following cables in the cable duct
3
on the
inside of the boiler cladding:
- Plate slide back-burning protection
- Temperature sensor for the feed auger
- Feed auger motor
2
1
1
2
3
Summary of Contents for Therminator II
Page 39: ...Annex Installation manual therminator II touch 39 9 6 Commissioning log ...
Page 40: ...Annex 40 Installation manual therminator II touch ...
Page 41: ...Annex Installation manual therminator II touch 41 9 7 Customer service order form ...
Page 42: ...Annex 42 Installation manual therminator II touch ...
Page 43: ...Annex Installation manual therminator II touch 43 ...