ID Status
This screen displays the inverter software version and the country to which the inverter is configured.
I D : # # # # # # # # # #
D S P 1 / 2 : 1 . 0 2 1 0 / 1 . 0 0 3 4
C P U : 0 0 0 3 . 1 4 x x
C o u n t r y : U S A 1
l
ID
: The inverter ID.
l
DSP 1/2
: The DSP digital control board firmware version
l
CPU
: The communication board firmware version
l
Country
: the current country setting
Server Communication Status
S e r v e r : L A N
< S _ O K >
S t a t u s :
< O K >
x x x x x x x x
< E R R O R M E S S A G E >
NOTE
If the connection method is CDMA (Cellular) or GSM, the server screen is replaced with the Cellular
or GSM status screens (see
Cellular Status
on the next page and
GSM Status
on the next page).
l
Server
: The method of connection to the SolarEdge monitoring portal.
l
S_OK
: The connection to the SolarEdge monitoring portal is successful (should appear only if the
inverter is connected to the server).
l
Status
: Displays OK if the inverter established successful connection and communication with the
specified server port/device (LAN, RS485 or ZigBee module).
l
xxxxxxxx
: Eight-bit Ethernet communication connection status: A string of 1s and 0s is displayed. 1
indicates OK, 0 indicates an error. For a list of the possible errors and how to troubleshoot them, refer
to
Communication Troubleshooting
on page 79.
l
Error message
, according to failure. Refer to
Errors and Troubleshooting
on page 1.
IP Status
This screen describes the Ethernet configuration: IP, Mask, Gateway and MAC address (Media Access
Control) of the Inverter.
I P
1 9 2 . 1 6 8 . 2 . 1 1 9
M S K 2 5 5 . 2 5 5 . 2 5 5 . 0
G W
1 9 2 . 1 6 8 . 2 . 1
M A C 0 - 2 7 - 0 2 - 0 0 - 3 9 - 3 6
ZigBee Status
This screen describes the ZigBee configuration:
P A N : X X X X X
C H : X X / X X X X
R S S I : < L >
M I D : X X X X X X
Chapter 7: User Interface
SolarEdge
-
StorEdge Installation Guide MAN-01-00262-1.0