Connecting Communication to the Meter
Prepare cables and connect the communication wires as described in the following table. For detailed
information refer to the installation guide supplied with the meter.
Recommended cable type
(min-max AWG)
External Devices
connection
Meter connection
RS485 24 AWG (16-24 AWG),
shielded twisted pair, 600V
insulated
Ext. Devices 7-pin terminal
block: B, A, G
RS485 4-pin terminal block: B, A, G
If you have a meter with SolarEdge label, connect as illustrated below:
Figure 23: Connection to a meter (SolarEdge
If you have a meter with WattNode label, connect as illustrated below:
Figure 24: Connection to a meter (WattNode)
Chapter 6: StorEdge Inverter Connections
SolarEdge
-
StorEdge Installation Guide MAN-01-00262-1.0
37