- 40 -
Para protect
1 to 2
Sets the range in which parameter and step data can be
changed.
Value
Description
1
Basic par
Return to origin parameter
+ Step data
2
Basic par
Return to origin parameter
XX
Enable SW
1 to 2
This defines the status of the Enable switch of the teaching
box.
Value
Description
1
Enable
2
Disable
XX
Unit name
Fixed value
Indication of the electric actuator type compatible to the driver.
(It should not be changed)
-
W-AREA1
“Stroke(-)”to
“Stroke (+)”
of the basic
parameter
The setting to define the conditions where the WAREA output
will be turned ON (Unit: mm)
If the current position is within the range between the W-AREA1
and W-AREA2, the WAREA output will be turned ON.
If W-AREA1 >W-AREA2, the alarm “Parameter ALM” will be
activated.(However,no alarm is generated if “W-AREA1”= W-
“AREA2”= 0, the WAREA output will be turned OFF)
XX
W-AREA2
“Stroke(-)”to
“Stroke (+)”
of the basic
parameter
XX
ORG Correct
[Link Offset]
Fixed value
This is the fixed value for this driver.
(It should not be changed)
-
Sensor type
-