<Countermeasure>
Make sure there are no obstructions that interfere with the
electric
actuator
movement and then, turn on the servo motor (SVON is turned on).
Over current
(
1-194
)
E
Power
off
<Contents>
The output current of the power circuit is extraordinarily high.
<Countermeasure>
Make sure that there are no short circuits of actuator cables, connectors, etc.
In addition, make sure that the
electric
actuator conforms to the driver.
I sens ALM
(
1-195
)
E
Power
off
<Contents>
An abnormality is detected by the current sensor that is checked when the
driver is reset.
<Countermeasure>
Make sure that the
electric
actuator conforms to the driver. Even after this
measure, if the alarm regenerates when the power is reapplied, please
contact SMC.
Err overflow
(1-196)
E
Power
off
<Contents>
Position deviation counter in the driver has overflowed during JOG or
MOVE operation.
<Countermeasure>
Check if the travel of the electric actuator is interrupted.
Check if the load
of the
electric
actuator
is within the specification range.
Memory
ALM
(
1-197
)
E
Power
off
<Contents>
An error of the EEPROM is occurred.
<Countermeasure>
Please contact SMC
(The EEPROM can be re-written up to approximately 100,000 times).
CPU ALM
(
1-198
)
E
Power
off
<Contents>
The CPU is not operating normally.
(It is possible that the CPU or surrounding circuits is failed or a malfunction
of the CPU is occurred due to an electric noise).
<Countermeasure>
If the alarm cannot be deactivated even after the power is reapplied, please
contact SMC.